Mostra el registre d'ítem simple

dc.contributor.authorNejjari Akhi-Elarab, Fatiha
dc.contributor.authorPérez Magrané, Ramon
dc.contributor.authorPuig Cayuela, Vicenç
dc.contributor.authorQuevedo Casín, Joseba Jokin
dc.contributor.authorCugueró Escofet, Miquel Àngel
dc.contributor.authorSanz Estapé, Gerard
dc.contributor.authorMirats Tur, Josep Maria
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2011-11-16T08:49:43Z
dc.date.available2011-11-16T08:49:43Z
dc.date.created2011
dc.date.issued2011
dc.identifier.citationNejjari, F. [et al.]. Abnormal quality detection and isolation in water distribution networks using simulation models. A: International Conference on Computing and Control for the Water Industry. "11th International Conference on Computing and Control for the Water Industry". Exeter: 2011, p. 461-466.
dc.identifier.isbn0-9539140-5-4
dc.identifier.urihttp://hdl.handle.net/2117/13919
dc.descriptionThis paper proposes a model based fault localisation method to deal with abnormal quality levels based on the chlorine measurements and chlorine sensitivity analysis in a water distribution network. A fault isolation algorithm which correlates on line the residuals, generated by comparing the available chlorine measurements with their estimation using a model, with the fault sensitivity matrix is used. The proposed methodology has been applied to a District Metered Area (DMA) in the Barcelona network.
dc.format.extent6 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Informàtica::Automàtica i control
dc.subject.lcshWater -- Quality
dc.subject.lcshWater -- Distribution
dc.subject.lcshSystem failures (Engineering)
dc.titleAbnormal quality detection and isolation in water distribution networks using simulation models
dc.typeConference report
dc.subject.lemacAigua -- Qualitat
dc.subject.lemacAigua -- Distribució
dc.subject.lemacErrors de sistemes (Enginyeria) -- Localització
dc.contributor.groupUniversitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control
dc.description.peerreviewedPeer Reviewed
dc.rights.accessRestricted access - author's decision
local.identifier.drac7729526
dc.description.versionPostprint (published version)
local.citation.authorNejjari, F.; Pérez, R.; Puig, V.; Quevedo, J.; Cuguero, M.; Sanz, G.; Mirats, J.
local.citation.contributorInternational Conference on Computing and Control for the Water Industry
local.citation.pubplaceExeter
local.citation.publicationName11th International Conference on Computing and Control for the Water Industry
local.citation.startingPage461
local.citation.endingPage466


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple