Mostra el registre d'ítem simple

dc.contributor.authorMuñoz, Juan Jorge
dc.contributor.authorTarantino, A
dc.contributor.authorGallipoli, Domenico
dc.contributor.authorAugarde, C. E.
dc.contributor.authorGennaro, V. de
dc.contributor.authorGómez Bonilla, Rodrigo Andrés
dc.contributor.authorLaloui, L.
dc.contributor.authorMancuso, C.
dc.contributor.authorEl Mountassir, G.
dc.contributor.authorWheeler, S. J.
dc.contributor.authorTombolato, S.
dc.contributor.authorToll, D. G.
dc.contributor.authorRojas Arias, Juan Carlos
dc.contributor.authorRaveendiraraj, A.
dc.contributor.authorRomero Morales, Enrique Edgar
dc.contributor.authorPisoni, G.
dc.contributor.authorPeron, H.
dc.contributor.authorPereira, J.-M.
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria del Terreny, Cartogràfica i Geofísica
dc.date.accessioned2011-09-20T12:42:58Z
dc.date.available2011-09-20T12:42:58Z
dc.date.created2011
dc.date.issued2011
dc.identifier.citationTarantino, A. [et al.]. Benchmark of experimental techniques for measuring and controlling suction. "Géotechnique", 2011, vol. 61, núm. 4, p. 303-312.
dc.identifier.issn0016-8505
dc.identifier.urihttp://hdl.handle.net/2117/13273
dc.description.abstractThe paper presents a benchmarking study carried out within the ‘Mechanics of Unsaturated Soils for Engineering’ (MUSE) network aimed at comparing different techniques for measurement and control of suction. Techniques tested by the eight ‘Mechanics of Unsaturated Soils for Engineering’ research teams include axis-translation (pressure plate and suction-controlled oedometer), highcapacity tensiometer and osmotic technique. The soil used in the exercise was a mixture of uniform sand, sodium bentonite (active clay) and kaolinite (non-active clay), which were all commercially available. Samples were prepared by one team and distributed to all other teams. They were normally consolidated from slurry under one-dimensional conditions (consolidometer) to a given vertical stress. The water retention characteristics of the initially saturated specimens were investigated along the main drying path. Specimens were de-saturated by applying suction through the liquid phase when using an axis-translation technique or osmotic method and de-saturated by air-drying, when suction was measured using igh-capacity tensiometers. In general, the same technique was tested by at least two teams. The water retention curves obtained using the different techniques are compared and discrepancies are discussed in the paper.
dc.format.extent10 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Geotècnia
dc.subject.lcshSubduction (Geology) -- Experiments
dc.titleBenchmark of experimental techniques for measuring and controlling suction
dc.typeArticle
dc.contributor.groupUniversitat Politècnica de Catalunya. MSR - Mecànica del Sòls i de les Roques
dc.identifier.doi10.1680/geot.2011.61.4.303
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://www.icevirtuallibrary.com/content/article/10.1680/geot.2011.61.4.303
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac5602772
dc.description.versionPostprint (published version)
local.citation.authorTarantino, A.; Gallipoli, D.; Augarde, C.; Gennaro, V.; Gómez, R.; Laloui, L.; Mancuso, C.; El Mountassir, G.; Muñoz, J.; Pereira, J.; Peron, H.; Pisoni, G.; Romero, E.; Raveendiraraj, A.; Rojas, J.; Toll, D.; Tombolato, S.; Wheeler, S.
local.citation.publicationNameGéotechnique
local.citation.volume61
local.citation.number4
local.citation.startingPage303
local.citation.endingPage312


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple