Air infiltration in Catalan dwellings and sealed rooms: An experimental study
Visualitza/Obre
Air infiltration in Catalan dwellings....pdf (343,2Kb) (Accés restringit)
Sol·licita una còpia a l'autor
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
10.1016/j.buildenv.2011.04.009
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/13108
Tipus de documentArticle
Data publicació2011-10
Condicions d'accésAccés restringit per política de l'editorial
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
Abstract
In this study, we performed a series of trials to measure the infiltration air exchange rate (ACH) of several
single-family dwellings throughout Catalonia, as well as the ACH of sealed rooms that could be used as indoor shelters. A shelter is an indoor room where people can take protection in case of a toxic gas
release, while the toxic cloud passes through the dwelling. Experimental measurements were made using the tracer gas decay technique with CO2 as the tracer gas in 2 periodsdsummer and winterdwith the aim of characterizing air infiltration in Catalan dwellings. The geometric means obtained for the ACH of shelters and dwellings were 0.16 and 0.23 h-1, respectively, that is, lower than those reported for North American (0.56 h-1) and Greek (0.76 h-1) dwellings. In general, the ACH was lower for shelters than for dwellings, and the average reduction btained in shelters with respect to dwellings was 35%. The largest reductions were obtained in old dwellings with small floor areas and few stories. As for meteorological conditions, we found that the ACH of dwellings was more closely linked to wind speed than indoore-outdoor temperature difference, while the ACH of shelters was more affected by indoore-outdoor temperature and temperature differences inside the dwelling, particularly in dwellings with 3 or more
stories.
CitacióMontoya, M.I.; Pastor, E.; Planas, E. Air infiltration in Catalan dwellings and sealed rooms: An experimental study. "Building and environment", Octubre 2011, vol. 46, núm. 10, p. 2003-2011.
ISSN0360-1323