Mostra el registre d'ítem simple

dc.contributor.authorCanal Barnils, Cristina
dc.contributor.authorVilleger, Sandrine
dc.contributor.authorRicard, André
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
dc.date.accessioned2011-08-24T10:37:40Z
dc.date.available2011-08-24T10:37:40Z
dc.date.created2011-06-22
dc.date.issued2011-06-22
dc.identifier.citationCanal, C.; Villeger, S.; Ricard, A. Evaluation of N atom transmission of N(2) flowing post-discharges for sterilization processes through modification of wettability of textiles. "Plasma processes and polymers", 22 Juny 2011, vol. 8, núm. 6, p. 505-511.
dc.identifier.issn1612-8850
dc.identifier.urihttp://hdl.handle.net/2117/13104
dc.description.abstractPlasma sterilization has been extensively studied in recent years, and at present conditioning materials such as sterilization pouches or process indicators devoted to such processes should be optimized to allow transfer of the technology to the market. The present work evaluates the possibility of using wettability modification of hydrophobic textiles to detect whether Natoms of a flowing post-discharge in sterilization conditions (1 L/min, 100W) are able to freely cross a cellulose membrane (found on the permeable side of a conventional sterilization pouch) and exert their action. Results showed that N2 postdischarge treatment did not alter pore size of the membrane, and the use of tailored hydrophobic textiles was shown to be an appropriate indicator of N atom penetration inside the pouches. Depending on the initial hydrophobic treatment of the textiles, it is possible to detect differences in the density of atoms which crossed the membrane, being capable of distinguishing between parameters such as treatment time, or altered hydrodynamics of the chamber.
dc.format.extent7 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria dels materials::Materials plàstics i polímers
dc.subject.lcshCellulose membrane
dc.subject.lcshMembrane filters
dc.subject.lcshPlasma sterilization
dc.subject.lcshWettability
dc.titleEvaluation of N atom transmission of N(2) flowing post-discharges for sterilization processes through modification of wettability of textiles
dc.typeArticle
dc.subject.lemacMembranes de cel.lulosa
dc.subject.lemacMullabilitat
dc.subject.lemacPlasma (Gasos ionitzats)
dc.contributor.groupUniversitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits
dc.identifier.doi10.1002/ppap.201000146
dc.description.peerreviewedPeer Reviewed
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac5837885
dc.description.versionPostprint (published version)
local.citation.authorCanal, C.; Villeger, S.; Ricard, A.
local.citation.publicationNamePlasma processes and polymers
local.citation.volume8
local.citation.number6
local.citation.startingPage505
local.citation.endingPage511