Mostra el registre d'ítem simple
Evaluation of N atom transmission of N(2) flowing post-discharges for sterilization processes through modification of wettability of textiles
dc.contributor.author | Canal Barnils, Cristina |
dc.contributor.author | Villeger, Sandrine |
dc.contributor.author | Ricard, André |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica |
dc.date.accessioned | 2011-08-24T10:37:40Z |
dc.date.available | 2011-08-24T10:37:40Z |
dc.date.created | 2011-06-22 |
dc.date.issued | 2011-06-22 |
dc.identifier.citation | Canal, C.; Villeger, S.; Ricard, A. Evaluation of N atom transmission of N(2) flowing post-discharges for sterilization processes through modification of wettability of textiles. "Plasma processes and polymers", 22 Juny 2011, vol. 8, núm. 6, p. 505-511. |
dc.identifier.issn | 1612-8850 |
dc.identifier.uri | http://hdl.handle.net/2117/13104 |
dc.description.abstract | Plasma sterilization has been extensively studied in recent years, and at present conditioning materials such as sterilization pouches or process indicators devoted to such processes should be optimized to allow transfer of the technology to the market. The present work evaluates the possibility of using wettability modification of hydrophobic textiles to detect whether Natoms of a flowing post-discharge in sterilization conditions (1 L/min, 100W) are able to freely cross a cellulose membrane (found on the permeable side of a conventional sterilization pouch) and exert their action. Results showed that N2 postdischarge treatment did not alter pore size of the membrane, and the use of tailored hydrophobic textiles was shown to be an appropriate indicator of N atom penetration inside the pouches. Depending on the initial hydrophobic treatment of the textiles, it is possible to detect differences in the density of atoms which crossed the membrane, being capable of distinguishing between parameters such as treatment time, or altered hydrodynamics of the chamber. |
dc.format.extent | 7 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria dels materials::Materials plàstics i polímers |
dc.subject.lcsh | Cellulose membrane |
dc.subject.lcsh | Membrane filters |
dc.subject.lcsh | Plasma sterilization |
dc.subject.lcsh | Wettability |
dc.title | Evaluation of N atom transmission of N(2) flowing post-discharges for sterilization processes through modification of wettability of textiles |
dc.type | Article |
dc.subject.lemac | Membranes de cel.lulosa |
dc.subject.lemac | Mullabilitat |
dc.subject.lemac | Plasma (Gasos ionitzats) |
dc.contributor.group | Universitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits |
dc.identifier.doi | 10.1002/ppap.201000146 |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 5837885 |
dc.description.version | Postprint (published version) |
local.citation.author | Canal, C.; Villeger, S.; Ricard, A. |
local.citation.publicationName | Plasma processes and polymers |
local.citation.volume | 8 |
local.citation.number | 6 |
local.citation.startingPage | 505 |
local.citation.endingPage | 511 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [960]
-