Mostra el registre d'ítem simple

dc.contributor.authorPouresmaeil, Edris
dc.contributor.authorMontesinos Miracle, Daniel
dc.contributor.authorGomis Bellmunt, Oriol
dc.contributor.authorSudrià Andreu, Antoni
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2011-07-13T10:13:10Z
dc.date.available2011-07-13T10:13:10Z
dc.date.created2010-12-07
dc.date.issued2010-12-07
dc.identifier.citationPouresmaeil, E. [et al.]. Instantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter. "European transactions on electrical power", 07 Desembre 2010, p. 1-16.
dc.identifier.issn1430-144X
dc.identifier.urihttp://hdl.handle.net/2117/12955
dc.description.abstractIn this paper, the synthesis and performance of a shunt active power filter (SAPF) based on instantaneous active, and reactive current components (i-d i-q) technique is presented. The proposed active filter acts as a current source, which is connected in parallel with a nonlinear load and controlled to generate the required compensation currents. The proposed control technique for SAPF aims to compensate the harmonic current contents of nonlinear loads by connection of distributed generation (DG) resources based on renewable energy sources to distribution network. This modeling is derived from the 123(abc)to αβ and αβ to dq transformation of the ac system variables. The injected currents by the SAPF to polluted grid are controlled in synchronous orthogonal dq reference frame by using of decoupled current control technique. By use of phase locked loop (PLL) in control circuit of proposed technique, the angle of positive sequence has been detected, in order to synchronize the SAPF injected currents to distribution network. The proposed control strategy has this ability to eliminate wide range of harmonic frequency draws from utility grid, and provide the compensation currents by DG resources. By this control method, replacement of distributed power generation systems as an active power filter can be possible. Three-phase three-level neutral-point-clamped (NPC) voltage source inverter (VSI) is proposed for the interfacing between renewable energy resources and polluted distribution network. The simulation results demonstrate high performances of proposed SAPF technique.
dc.format.extent16 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Energies::Energia elèctrica
dc.subject.lcshElectric current converters
dc.titleInstantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter
dc.typeArticle
dc.subject.lemacConvertidors de corrent elèctric
dc.contributor.groupUniversitat Politècnica de Catalunya. CITCEA - Centre d'Innovació Tecnològica en Convertidors Estàtics i Accionaments
dc.identifier.doi10.1002/etep.536
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://onlinelibrary.wiley.com/doi/10.1002/etep.536/full
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac5819232
dc.description.versionPostprint (published version)
local.citation.authorPouresmaeil, E.; Montesinos-Miracle, D.; Gomis-Bellmunt, O.; Sudrià, A.
local.citation.publicationNameEuropean transactions on electrical power
local.citation.startingPage1
local.citation.endingPage16


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple