Mostra el registre d'ítem simple

dc.contributor.authorGarde Martínez, Ainara
dc.contributor.authorSörnmo, Leif
dc.contributor.authorJané Campos, Raimon
dc.contributor.authorGiraldo Giraldo, Beatriz
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.contributor.otherInstitut de Bioenginyeria de Catalunya
dc.date.accessioned2011-06-21T21:13:02Z
dc.date.available2011-06-21T21:13:02Z
dc.date.created2010
dc.date.issued2010
dc.identifier.citationGarde, A. [et al.]. Correntropy-based nonlinearity test applied to patients with chronic heart failure. A: Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS). "32th Annual International Conference of the IEEE Engineering in Medicine and Biology Society". Buenos Aires: 2010, p. 2399-2402.
dc.identifier.urihttp://hdl.handle.net/2117/12807
dc.description.abstractIn this study we propose the correntropy function as a discriminative measure for detecting nonlinearities in the respiratory pattern of chronic heart failure (CHF) patients with periodic or nonperiodic breathing pattern (PB or nPB, respectively). The complexity seems to be reduced in CHF patients with higher risk level. Correntropy reflects information on both, statistical distribution and temporal structure of the underlying dataset. It is a suitable measure due to its capability to preserve nonlinear information. The null hypothesis considered is that the analyzed data is generated by a Gaussian linear stochastic process. Correntropy is used in a statistical test to reject the null hypothesis through surrogate data methods. Various parameters, derived from the correntropy and correntropy spectral density (CSD) to characterize the respiratory pattern, presented no significant differences when extracted from the iteratively refined amplitude adjusted Fourier transform (IAAFT) surrogate data. The ratio between the powers in the modulation and respiratory frequency bands R was significantly different in nPB patients, but not in PB patients, which reflects a higher presence of nonlinearities in nPB patients than in PB patients.
dc.format.extent4 p.
dc.language.isoeng
dc.subject.lcshHeart failure -- Diagnosis
dc.subject.lcshRespiratory organs -- Diseases
dc.titleCorrentropy-based nonlinearity test applied to patients with chronic heart failure
dc.typeConference report
dc.subject.lemacRespiració -- Mesurament
dc.subject.lemacCor -- Malalties -- Diagnòstic
dc.contributor.groupUniversitat Politècnica de Catalunya. SISBIO - Senyals i Sistemes Biomèdics
dc.identifier.doi10.1109/IEMBS.2010.5627167
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.identifier.drac5725145
dc.description.versionPostprint (published version)
local.citation.authorGarde, A.; Sörnmo, L.; Jané, R.; Giraldo, B. F.
local.citation.contributorAnnual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS)
local.citation.pubplaceBuenos Aires
local.citation.publicationName32th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
local.citation.startingPage2399
local.citation.endingPage2402


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple