Tracking sewage derived contamination in riverine settings by analysis of synthetic surfactants
Visualitza/Obre
Cita com:
hdl:2117/12729
Tipus de documentArticle
Data publicació2011-05-31
Condicions d'accésAccés obert
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
ProjecteBADEPAS - Behavior and distribution of emerging pollutants in aquatic systems (EC-FP7-221686)
Abstract
A study has been made of the presence and reactivity of the most commonly used surfactants, both anionic (linear alkylbenzene sulfonates, LAS, and alkyl ethoxysulfates, AES) and non-ionic (alcohol
polyethoxylates, AEOs, and nonylphenol polyethoxylates, NPEOs), in water and surface sediments from the middle stretch of the Guadalete River in SW Spain (12 stations). Average values were between
0.1 and 3.7 mg kg_1 in sediment, and between 0.2 and 37 mg L_1 in water. The sorption of surfactants was dominated by hydrophobic mechanisms, so those homologues having longer alkyl chains (e.g. C18AEO) showed higher relative percentages and concentrations in sediments compared with
water. Local and sharply higher concentrations of these compounds were observed at three sampling stations (7, 9 and 12), indicating the occurrence of wastewater discharges into the river. By analysing the distributions of different surfactant homologues and their metabolites we were able to distinguish between sewage contamination from sources discharging treated and untreated wastewaters. Upstream
(stations 1–2), LAS concentrations were below 30 mg L_1 and the composition of their degradation intermediates (sulfophenyl carboxylic acids, SPCs) (160 mg L_1) was dominated by short-chain homologues (C6–C9SPCs), indicating that the degradation of this surfactant is at an advanced stage.
The highest concentration (487 mg L_1) of SPCs was detected near the effluent outlet of a sewage treatment plant (STP) (station 12). Sampling stations (7 and 9) affected by untreated wastewater discharges were the only ones showing the presence of the most reactive and biodegradable SPC isomers and homologues (e.g. C11SPC). Here, LAS reached the highest concentration values measured
(>2 mg L_1), and showed a homologue distribution closer to that of commercial mixtures than LAS found at the other stations.
CitacióCorada-Fernández, C. [et al.]. Tracking sewage derived contamination in riverine settings by analysis of synthetic surfactants. "Journal of environmental monitoring", 31 Maig 2011, p. 1-8.
ISSN1464-0325
Versió de l'editorhttp://pubs.rsc.org/en/content/articlepdf/2011/em/c1em10150a
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
5778762.pdf | 364,7Kb | Visualitza/Obre |