Abstract
Purpose. The purpose of the present work is to understand and study the mechanical behavior and critical parameters of
ophthalmic polymers. The article introduces a novel low-energy indentation method that can be used to study and
optimize the mechanical properties of ophthalmic materials. The technique has been developed in the frame of a larger
study on the impact resistance of materials.
Method. The low-energy dynamic indentation method is based on a lumped mass-spring model solved by a 4th-order
Runge-Kutta numerical method. The model can be used to predict the material response to the indentation of a
hemi-spherical tip and calculate the elasticity modulus of materials, dissipated energy during impact, residual deformation
after impact, indentation depth and their conservative and nonconservative components.
Results. As an example, two ophthalmic polymers were compared: CR-39 as the universal ophthalmic standard, and
Superfin as Indo Lens U.S., standard. Results showed the model is in good agreement with experimental data and allowed
to obtain elasticity moduli for both materials, which showed similar values. A larger conservative component of the
displacement for Superfin was also obtained and a smaller calculated residual displacement, which is indicative of less
deformed material after low energy impacts.
Conclusions. The model can satisfactorily predict the behavior of materials under low energy indentation situations. In
addition, it can be used to distinguish two apparently similar materials, such as CR-39 and Superfin, and classify them
according to their response to these kind of indentations. The technique could be used as a very powerful tool to improve
ophthalmic materials