Alternative conducted immunity tests
Visualitza/Obre
Cita com:
hdl:2117/103394
Tipus de documentArticle
Data publicació2016-12-14
Condicions d'accésAccés obert
Llevat que s'hi indiqui el contrari, els
continguts d'aquesta obra estan subjectes a la llicència de Creative Commons
:
Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya
Abstract
Conducted immunity tests are always performed by the use of CDNs in laboratories in accordance with the standard EN61000-4-6. However, it is not always possible to use CDNs because of some limitations. If the EUT (Equipment Under Test) has large dimensions or high currents, it is not, most of the time, possible to send it to an EMC laboratory or to use CDNs during the test. As a consequence, usage of BCI probes is inevitable in industry. In this paper, we compared the laboratory setup installed with CDNs and alternative setups installed directly on mains without any CDNs in terms of loop impedances and injected loop currents. We also established a link based on the loop impedances and the injected currents on the test loops between the two setups. Finally, a first serious step was taken to establish the fundamentals of alternative conducted immunity tests based on the impedance measurements of test loops for industry.
CitacióCakir, S., Azpurua, M. A., Silva, F., Cetintas, M. Alternative conducted immunity tests. "IEEE Electromagnetic Compatibility Magazine", 14 Desembre 2016, vol. 5, núm. 3, p. 45-51.
ISSN2162-2264