DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/9398

Arxiu Descripció MidaFormat
romero 2008.pdfarticle principal1,06 MBAdobe PDFThumbnail
Veure/Obrir

Citació: Romero, S.; Mañanas, M.; Barbanoj, M. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case. "Computers in biology and medicine", Març 2008, vol. 38, núm. 3, p. 348-360.
Títol: A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case
Autor: Romero Lafuente, Sergio Veure Producció científica UPC; Mañanas Villanueva, Miguel Ángel Veure Producció científica UPC; Barbanoj, Manel J. Veure Producció científica UPC
Editorial: ELSEVIER
Data: mar-2008
Tipus de document: Article
Resum: Eye movement artifacts represent a critical issue for quantitative electroencephalography (EEG) analysis and a number of mathematical approaches have been proposed to reduce their contribution in EEG recordings. The aim of this paper was to objectively and quantitatively evaluate the performance of ocular filtering methods with respect to spectral target variables widely used in clinical and functional EEG studies. In particular the following methods were applied: regression analysis and some blind source separation (BSS) techniques based on second-order statistics (PCA, AMUSE and SOBI) and on higher-order statistics (JADE, INFOMAX and FASTICA). Considering blind source decomposition methods, a completely automatic procedure of BSS based on logical rules related to spectral and topographical information was proposed in order to identify the components related to ocular interference. The automatic procedure was applied in different montages of simulated EEG and electrooculography (EOG) recordings: a full montage with 19 EEG and 2 EOG channels, a reduced one with only 6 EEG leads and a third one where EOG channels were not available. Time and frequency results in all of them indicated that AMUSE and SOBI algorithms preserved and recovered more brain activity than the other methods mainly at anterior regions. In the case of full montage: (i) errors were lower than 5% for all spectral variables at anterior sites; and (ii) the highest improvement in the signal-to-artifact (SAR) ratio was obtained up to 40 dB at these anterior sites. Finally, we concluded that second-order BSS-based algorithms (AMUSE and SOBI)
ISSN: 0010-4825
URI: http://hdl.handle.net/2117/9398
DOI: 10.1016/j.compbiomed.2007.12.001
Versió de l'editor: http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6T5N-4RPD7H7-2&_user=1517299&_coverDate=03%2F31%2F2008&_rdoc=1&_fmt=high&_orig=search&_sort=d&_docanchor=&view=c&_acct=C000053450&_version=1&_urlVersion=0&_userid=1517299&md5=0839b0c165595fef6e47b222520d9528
Apareix a les col·leccions:SISBIO - Senyals i Sistemes Biomèdics. Articles de revista
Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Aquest ítem (excepte textos i imatges no creats per l'autor) està subjecte a una llicència de Creative Commons Llicència Creative Commons
Creative Commons

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius