| Citació: | Nescolarde Selva, Lexa. [et al.]. Applications of longitudinal and transversal bioimpedance measurements in peritoneal dialysis at 50 kHz. A: XIVth International Conference on Electrical Bioimpedance. "XIVth International Conference on Electrical Bioimpedance". Gainesville-Florida, April 04-08: 2010, p. 1-4. |
| Títol: | Applications of longitudinal and transversal bioimpedance measurements in peritoneal dialysis at 50 kHz |
| Autor: | Nescolarde Selva, Lexa Digna ; Doñate, T.; Casañas Bueno, Roberto ; Rosell Ferrer, Francisco Javier  |
| Data: | 2010 |
| Tipus de document: | Conference report |
| Resum: | More relevant information of the fluid changes in peritoneal dialysis (PD) might be
obtained with segmental bioimpedance measurements rather than whole-body measurement,
who hidden information of body composition. Whole-body and segmental bioimpedance
measurements were obtained using 5 configurations (whole-body or right-side (RS),
longitudinal-leg (L-LEG), longitudinal-abdomen (L-AB), transversal-abdomen (T-AB), and
transversal-leg (T-LEG)) in 20 patients: 15 males (56.5 ± 9.4 yr, 24.2 ± 4.2 kg/m2) and 5
females (58.4 ± 7.1 yr, 28.2 ± 5.9 kg/m2) in peritoneal dialysis (PD). The aim of this study is to
analyze the relationship between whole-body, longitudinal-segmental (L-LEG and L-AB) and
transversal-segmental (TAB and TLEG) bioimpedance measurement at 50 kHz, with clinical
parameters of cardiovascular risk, dyslipidemia, nutrition and hydration. The Kolmogorov-
Smirnov test was used for the normality test of all variables. Longitudinal bioimpedance
parameters were normalized by the height of the patients. The Spearman correlation was used
to analyze the correlation between bioimpedance and clinical parameters. The statistical
significance was considered with P < 0.05. Transversal bioimpedance measurements have
higher correlation with clinical parameters than longitudinal measurements. |