DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/7648

Arxiu Descripció MidaFormat
penMesh.pdf1,18 MBAdobe PDFThumbnail
Veure/Obrir

Citació: BADAL, A. [et al.]. PenMesh-Monte Carlo radiation transport simulation in a triangle mesh geometry. "IEEE transactions on medical imaging", Desembre 2009, vol. 28, núm. 12, p. 1894-1901.
Títol: PenMesh-Monte Carlo radiation transport simulation in a triangle mesh geometry
Autor: Badal Soler, Andreu; Kyprianou, Iacovos; Banh, Diem Phuc; Badano, Aldo; Sempau Roma, Josep Veure Producció científica UPC
Data: des-2009
Tipus de document: Article
Resum: We have developed a general-purpose Monte Carlo simulation code, called penMesh, that combines the accuracy of the radiation transport physics subroutines from PENELOPE and the flexibility of a geometry based on triangle meshes. While the geometric models implemented in most general-purpose codes-such as PENELOPE's quadric geometry-impose some limitations in the shape of the objects that can be simulated, triangle meshes can be used to describe any free-form (arbitrary) object. Triangle meshes are extensively used in computer-aided design and computer graphics. We took advantage of the sophisticated tools already developed in these fields, such as an octree structure and an efficient ray-triangle intersection algorithm, to significantly accelerate the triangle mesh ray-tracing. A detailed description of the new simulation code and its ray-tracing algorithm is provided in this paper. Furthermore, we show how it can be readily used in medical imaging applications thanks to the detailed anatomical phantoms already available. In particular, we present a whole body radiography simulation using a triangulated version of the anthropomorphic NCAT phantom. An example simulation of scatter fraction measurements using a standardized abdomen and lumbar spine phantom, and a benchmark of the triangle mesh and quadric geometries in the ray-tracing of a mathematical breast model, are also presented to show some of the capabilities of penMesh.
ISSN: 0278-0062
URI: http://hdl.handle.net/2117/7648
DOI: 10.1109/TMI.2009.2021615
Apareix a les col·leccions:GREENER - Grup de recerca d´estudis energètics i de les radiacions. Articles de revista
Institut de Tècniques Energètiques. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Aquest ítem (excepte textos i imatges no creats per l'autor) està subjecte a una llicència de Creative Commons Llicència Creative Commons
Creative Commons

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius