Citació: Morgenstern, C.R. [et al.]. Automatic differentiation of obstructive and central hypopneas with esophageal pressure measurement during sleep. A: IEEE Engineering in Medicine and Biology Society. Conference. "31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society". Minneapolis, Minnesota: 2009, p. 7102-7105.
Títol: Automatic differentiation of obstructive and central hypopneas with esophageal pressure measurement during sleep
Autor: Morgenstern de Muller, Christian Rudolf Veure Producció científica UPC; Schwaibold, Matthias; Randerath, Winfried J.; Bolz, Armin; Jané Campos, Raimon Veure Producció científica UPC
Data: 2009
Tipus de document: Conference report
Resum: The differentiation between obstructive and central respiratory events is one of the most recurrent tasks in the diagnosis of sleep disordered breathing. Esophageal pressure measurement is the gold-standard method to assess respiratory effort and identify these events. But as its invasiveness discourages its use in clinical routine, noninvasisve systems have been proposed for differentiation. However, their adoption has been slow due to their limited clinical validation, as the creation of manual, gold-standard validation sets by human experts is a cumbersome procedure. In this study, a new system is proposed for an objective automatic, gold-standard differentiation between obstructive and central hypopneas with the esophageal pressure signal. First, an overall of 356 hypopneas of 16 patients were manually scored by a human expert to create a gold-standard validation set. Then, features were extracted from each hypopnea to train and test classifiers (Discriminant Analysis, Support Vector Machines and adaboost classifiers) to differentiate between central and obstructive hypopneas with the gold-standard esophageal pressure signal. The automatic differentiation system achieved promising results, with a sensitivity of 0.88, a specificity of 0.93 and an accuracy of 0.90. Hence, this system seems promising for an automatic, gold-standard differentiation between obstructive and central hypopneas.
ISBN: 978-1-4244-3296-7/09
URI: http://hdl.handle.net/2117/7535
DOI: 10.1109/IEMBS.2009.5332900
Versió de l'editor: http://ieeexplore.ieee.org/search/freesrchabstract.jsp?tp=&arnumber=5332900&queryText%3Dmorgenstern+c%26openedRefinements%3D*%26searchField%3DSearch+All
Apareix a les col·leccions:SISBIO - Senyals i Sistemes Biomèdics. Ponències/Comunicacions de congressos
Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial. Ponències/Comunicacions de congressos
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius