Arxiu Descripció MidaFormat
Infilitration tests at the Sant Vicenç dels Horts artificial recharge experimental site.pdfActa del congrés37,88 kBAdobe PDFThumbnail
Veure/Obrir

Citació: Barahona-Palomo, M.; Pedretti, D.; Sanchez, F. Infilitration tests at the Sant Vicenç dels Horts artificial recharge experimental site. A: EGU General Assembly. "EGU General Assembly 2010". Viena: 2010, p. 1.
Títol: Infilitration tests at the Sant Vicenç dels Horts artificial recharge experimental site
Autor: Barahona-Palomo, Marco Veure Producció científica UPC; Pedretti, Daniele Veure Producció científica UPC; Sánchez Vila, Francisco Javier Veure Producció científica UPC
Data: 7-mai-2010
Tipus de document: Conference report
Resum: Infiltration capacity is the key parameter in an artificial recharge operation site. Infiltration capacity is spatially variable, and during operation it is also temporally variable due to surface clogging processes. Double-ring infiltrometer tests were performed at an experimental site close to Barcelona city (Spain). The site is located on alluvial deposits from the Llobregat River and comprises two half hectare ponds. River water collected upstream traveled through a two km pipe before entering the settling pond. Once the pond is filled water flows to the infiltration pond. Tests were performed only in the latter, prior to and after recharging the ponds. Prior to recharge, six points were selected to estimate infiltration capacity Points were evenly distributed and chosen considering apparent soil texture at the site (coarse, medium and fine grains). All tests were performed allowing water to infiltrate for two hours and data was interpreted using the modified Kostiakov equation. Ponds were then flooded for about two months. The average infiltration rate values for the full infiltration pond before and after the flooding campaign were 5.8 m/day and 2.2 m/day, respectively. The double ring tests were then repeated at the same points, showing a reduction of the infiltration rate that varied between 7 and 90%. Control points with the initial highest infiltration rates presented the highest reduction in infiltration. Physical clogging due to particles settling appears to be the most likely cause of the diminished infiltration rates. This result is confirmed by other independent measurements during the flooding test. There is a clear tendency towards a lower infiltration rates when observing the relation through time of flow entering per volume of water on the infiltration pond at a given time.
URI: http://hdl.handle.net/2117/7529
Versió de l'editor: http://meetings.copernicus.org/egu2010/home.html
Apareix a les col·leccions:GHS - Grup d'Hidrologia Subterrània. Ponències/Comunicacions de congressos
ETCG – Departament d’Enginyeria del Terreny, Cartogràfica i Geofísica. Ponències/Comunicacions de congressos
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius