Citació: Morales, S. [et al.]. Numerical analysis of two-phase flow in condensers and evaporators with special emphasis on single-phase/two-phase transition zones. "Applied thermal engineering", 01 Abril 2009, vol. 29, núm. 5-6, p. 1032-1042.
Títol: Numerical analysis of two-phase flow in condensers and evaporators with special emphasis on single-phase/two-phase transition zones
Autor: Morales Ruíz, Sergio Veure Producció científica UPC; Rigola Serrano, Joaquim Veure Producció científica UPC; Pérez Segarra, Carlos David Veure Producció científica UPC; García-Valladares, O
Data: 1-abr-2009
Tipus de document: Article
Resum: A numerical study of the thermal and fluid-dynamic behaviour of the two-phase flow in ducts under condensation or evaporation phenomena is presented. The numerical simulation has been developed by means of the finite volume technique based on a one-dimensional and transient integration of the conservative equations (continuity, momentum and energy). The discretized governing equations are solved using the Semi-Implicit Method for Pressure-Linked Equations (SIMPLE) which allows back flow phenomena. Special emphasis is performed on the treatment of the transition zones between the single-phase and two-phase flow. The empirical inputs of single-phase and two-phase flow, including sub-cooled boiling and dry-out, have been adapted by means of adequate splines in the transition zones where the heat transfer correlations available in the literature are not suitable. Different numerical aspects have been evaluated with the aim of verifying the quality of the numerical solution. The mathematical model has been validated by comparison with experimental data obtained from literature considering condensation and evaporation processes. This comparison shown the improvements in the numerical solution not only in the transition zone but also in all condenser and evaporator ducts, when the special treatment for transitions is used. Illustrative results on double-pipe heat exchanger are also presented.
ISSN: 1359-4311
URI: http://hdl.handle.net/2117/6894
DOI: http://dx.doi.org/10.1016/j.applthermaleng.2008.05.017
Apareix a les col·leccions:CTTC - Centre Tecnològic de la Transferència de Calor. Articles de revista
Departament de Màquines i Motors Tèrmics. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius