| Citació: | Morales, S. [et al.]. Numerical analysis of two-phase flow in condensers and evaporators with special emphasis on single-phase/two-phase transition zones. "Applied thermal engineering", 01 Abril 2009, vol. 29, núm. 5-6, p. 1032-1042. |
| Títol: | Numerical analysis of two-phase flow in condensers and evaporators with special emphasis on single-phase/two-phase transition zones |
| Autor: | Morales Ruíz, Sergio ; Rigola Serrano, Joaquim ; Pérez Segarra, Carlos David ; García-Valladares, O |
| Data: | 1-abr-2009 |
| Tipus de document: | Article |
| Resum: | A numerical study of the thermal and fluid-dynamic behaviour of the two-phase flow in ducts under condensation or evaporation phenomena is presented. The numerical simulation has been developed by means of the finite volume technique based on a one-dimensional and transient integration of the conservative equations (continuity, momentum and energy). The discretized governing equations are solved using the Semi-Implicit Method for Pressure-Linked Equations (SIMPLE) which allows back flow phenomena.
Special emphasis is performed on the treatment of the transition zones between the single-phase and two-phase flow. The empirical inputs of single-phase and two-phase flow, including sub-cooled boiling
and dry-out, have been adapted by means of adequate splines in the transition zones where the heat transfer correlations available in the literature are not suitable. Different numerical aspects have been evaluated with the aim of verifying the quality of the numerical solution. The mathematical model has been validated by comparison with experimental data obtained from literature considering condensation
and evaporation processes. This comparison shown the improvements in the numerical solution not only in the transition zone but also in all condenser and evaporator ducts, when the special treatment for transitions
is used. Illustrative results on double-pipe heat exchanger are also presented. |
| ISSN: | 1359-4311 |
| URI: | http://hdl.handle.net/2117/6894 |
| Versió de l'editor: | http://dx.doi.org/10.1016/j.applthermaleng.2008.05.017 |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC CTTC - Centre Tecnològic de la Transferència de Calor. Articles de revista Departament de Màquines i Motors Tèrmics. Articles de revista
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).
Per a qualsevol ús que es vulgui fer diferent al permès, dirigiu-vos a: sepi@upc.edu
|