DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/6614

Arxiu Descripció MidaFormat
Determining indoor air quality.pdf293,84 kBAdobe PDFThumbnail
Veure/Obrir

Citació: Gallego, E. [et al.]. Determining indoor air quality and identifying the origin of odour episodes in indoor environments. "Journal of environmental sciences (China)", 03 Març 2009, vol. 21, p. 333-339.
Títol: Determining indoor air quality and identifying the origin of odour episodes in indoor environments
Autor: Gallego Piñol, Eva Veure Producció científica UPC; Roca Mussons, Francisco Javier Veure Producció científica UPC; Perales Lorente, José Francisco Veure Producció científica UPC; Guardino, Xavier
Data: 3-mar-2009
Tipus de document: Article
Resum: A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 ± 1.53 mg/m3) compared to outdoor air (0.71 ± 0.46 mg/m3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.
ISSN: 1001-0742
URI: http://hdl.handle.net/2117/6614
Versió de l'editor: www.jesc.ac.cn
Apareix a les col·leccions:CEPIMA - Centre d´Enginyeria de Processos i Medi Ambient. Articles de revista
Departament d'Enginyeria Química. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius