Using central composite experimental design to optimize the degradation of real dye wastewater by Fenton and photo-Fenton reactions
Visualitza/Obre
Torrades, Fr. Using central composite experimental design to optimize the degradation ....pdf (496,2Kb) (Accés restringit)
Sol·licita una còpia a l'autor
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
10.1016/j.dyepig.2013.09.004
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/24009
Tipus de documentArticle
Data publicació2014-01
Condicions d'accésAccés restringit per política de l'editorial
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
Abstract
This work focuses on the use of Fenton reagent and UV-irradiation, in a lab-scale experiment, for the treatment of real dye wastewater coming from a Spanish textile manufacturer. Response surface methodology and a 23 factorial design were used to evaluate the effects of the three independent variables considered for the optimization of the oxidative process: temperature, Fe (II) and H2O2 concentrations, for a textile wastewater generated during a dyeing process with chemical oxygen demand of 1705 mg L_1 O2 at pH ¼ 3.Wastewater degradation was followed in terms of chemical oxygen demand reduction. In the optimization, the correlation coefficients for the model (R2) were 0.985 and 0.990 for Fenton and photo-Fenton treatments respectively. Optimum reaction conditions at pH ¼ 3 and temperature ¼ 298 K were [H2O2] ¼ 73.5 mM and [Fe(II)] ¼ 1.79 mM. The combination of Fenton, Fenton-like and photon-Fenton reactions has been proved to be highly effective for the treatment of such a type of wastewaters, and several advantages for this technique arise from the study. Under optimum conditions, 120 min of treatment resulted in a 62.9% and 76.3% reduction in chemical oxygen demand after Fenton and photo-Fenton treatments respectively
CitacióTorrades, F.; García-Montaño, J. Using central composite experimental design to optimize the degradation of real dye wastewater by Fenton and photo-Fenton reactions. "Dyes and pigments", Gener 2014, vol. 100, p. 184-189.