Citació: Camps, A.; Barà, J.; Corbella, I.; Torres, F. The processing of hexagonally sampled signals with standard rectangular techniques: application to 2D large aperture synthesis interferometric radiometers. IEEE Transactions on geoscience and remote sensing, 1997, vol. 35, núm. 1, p. 183-190.
Títol: The processing of hexagonally sampled signals with standard rectangular techniques: application to 2D large aperture synthesis interferometric radiometers
Autor: Camps Carmona, Adriano José Veure Producció científica UPC; Bará Temes, Francisco Javier Veure Producció científica UPC; Corbella Sanahuja, Ignasi Veure Producció científica UPC; Torres Torres, Francisco Veure Producció científica UPC
Editorial: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Data: 8-ago-1995
Tipus de document: Article
Resum: In Earth observation programs there is a need of passive low frequency (L-band) measurements to monitor soil moisture and ocean salinity with high spatial resolution 10-20 km, a radiometric resolution of 1 K and a revisit time of 1-3 days. Compared to total power radiometers aperture synthesis interferometric radiometers are technologically attractive because of their reduced mass and hardware requirements. In this field it should be mentioned the one-dimensional (1D) linear interferometer ESTAR developed by NASA and MIRAS a two-dimensional (2D) Y-shaped interferometer currently under study by European Space Agency (ESA). Interferometer radiometers measure the correlation between pairs of nondirective antennas. Each complex correlation is a sample of the “visibility” function which, in the ideal case, is the spatial Fourier transform of the brightness temperature distribution. Since most receiver phase and amplitude errors can be hardware calibrated, Fourier based iterative inversion methods will be useful when antenna errors are small, their radiation voltage patterns are not too different, and mutual coupling is small. In order to minimize on-board hardware requirements-antennas, receivers and correlators-the choice of the interferometer array shape is of great importance since it determines the (u,v) sampling strategy and the minimum number of visibility samples required for a determined aliasing level. In this sense, Y-shaped and triangular-shaped arrays with equally spaced antennas are optimal. The main contribution of this paper is a technique that allows the authors to process the visibility samples over the hexagonal sampling grids given by Y-shaped and triangular-shaped arrays with standard rectangular FFT routines. Since no interpolation processes are involved, the risk of induced artifacts in the recovered brightness temperature over the wide held of view required in Earth observation missions is minimized and signal to noise ratio (SNR) is preserved.
ISSN: 0196-2892
URI: http://hdl.handle.net/2117/1970
Apareix a les col·leccions:RSLAB - Remote Sensing Research Group. Articles de revista
Departament de Teoria del Senyal i Comunicacions. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius