Impact of the local oscillator calibration on the SMOS sea surface salinity maps
Visualitza/Obre
Impact of the Local Oscillator calibration on the SMOS sea surface Salinity maps (465,4Kb) (Accés restringit)
Sol·licita una còpia a l'autor
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
10.1109/IGARSS.2012.6350940
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/18757
Tipus de documentText en actes de congrés
Data publicació2012
EditorInstitute of Electrical and Electronics Engineers (IEEE)
Condicions d'accésAccés restringit per política de l'editorial
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
Abstract
The Local Oscillators (LO) of the Microwave Imaging Radiometer using Aperture Synthesis (MIRAS) onboard the Soil Moisture and Ocean Salinity (SMOS) satellite are used to maintain the operating frequency of the 69 receivers. The phase of the LO drifts over time, in turn blurring the MIRAS brightness temperature (TB) measurements. After a pre-launch assessment, it was decided to calibrate the LO every 10 minutes to reduce the phase drifts. During short periods of the first 2.5 years of SMOS mission, the LO calibration has been performed every 2 minutes to assess the impact of a higher calibration frequency on the quality of the data. In this study, relative differences (10-min TBs versus 2-min TBs) of about 0.3 K are shown, which lead to non-negligible relative differences of about 0.2-0.3 practical salinity units (psu) in the retrieved sea surface salinity (SSS). However, when performing independent validation against Argo float SSS data at Level 3 (spatio-temporally averaged SSS products), no significant differences are found between 10-min and 2-min data. This is due to the fact that current SMOS SSS accuracy (relative to Argo) is about 0.6-0.8 psu, thus masking the relatively smaller LO calibration frequency effect.
CitacióGabarro, C. [et al.]. Impact of the local oscillator calibration on the SMOS sea surface salinity maps. A: IEEE International Geoscience and Remote Sensing Symposium. "IGARSS 2012: International Geoscience and Remote Sensing Symposium". Munich: Institute of Electrical and Electronics Engineers (IEEE), 2012, p. 2613-2616.
ISBN978-1-4673-1159-5
Versió de l'editorhttp://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6350940
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
Impact of the L ... surface Salinity maps .pdf | Impact of the Local Oscillator calibration on the SMOS sea surface Salinity maps | 465,4Kb | Accés restringit |