| IASTED 2012_Ramo_764-104_Improvement.pdf | text complet | 508.01 kB | Adobe PDF |  |
|
| Citació: | Garcia, M. [et al.]. Improvement of the actimetry agreement among sites by proper choice of signal processing stages. A: IASTED International Conference Biomedical Engineering (BioMed). "Proceedings of the ninth IASTED International Conference Biomedical Engineering (BioMed 2012)". Innsbruck: 2012, p. 1-5. |
| Títol: | Improvement of the actimetry agreement among sites by proper choice of signal processing stages |
| Autor: | García González, Miguel Ángel ; Giovinazzo, Giuseppe ; Gomez Bule, Rafael; Landi, Francesca; Ramos Castro, Juan José ; Rosell Ferrer, Francisco Javier  |
| Data: | 2012 |
| Tipus de document: | Conference report |
| Resum: | Physical activity (PA) has been identified as a key health indicator and has been assessed in multiple studies as the
study of cardiovascular diseases, diabetes mellitus, obesity and psychological conditions. For this reason the
use of accelerometers to quantify PA is widely accepted in either clinical/laboratory settings as well as in freeliving environments. The use of accelerometers in the measurement of PA is a relatively new technique and,
therefore, has been not standardized. The aim of this work is to study the influence of signal processing stages in the
estimation of PA while measuring simultaneously in three
different sites to provide robust indicators of activity in
front of changes in site measurement. With our
measurement we show that a proper choice of signal
processing steps can improve the agreement among
activity indices measured from different sites on the same
individual. The results also show that the most suited
index is the time above threshold. In this case, the best
combination of axes is by applying the quadratic mean,
the best filtering of axes is using a cut-off frequency of
around 1.5 Hz and a threshold to compute the index of
0.04 g. |
| ISBN: | 978-0-88986-909-7 |
| URI: | http://hdl.handle.net/2117/16310 |
| Versió de l'editor: | http://cataleg.upc.edu/record=b1405949~S1*cat |
| Apareix a les col·leccions: | Departament d'Enginyeria Electrònica. Ponències/Comunicacions de congressos IEB - Instrumentació Electrònica i Biomèdica. Ponències/Comunicacions de congressos Altres. Enviament des de DRAC
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).