Novel estimation of the electrical bioimpedance using the local polynomial method. application to in vivo real-time myocardium tissue impedance characterization during the cardiac cycle.pdf1,65 MBAdobe PDF Accés restringit

Citació: Sánchez, B. [et al.]. Novel estimation of the electrical bioimpedance using the local polynomial method. Application to in vivo real-time myocardium tissue impedance characterization during the cardiac cycle. "IEEE transactions on biomedical engineering", 18 Novembre 2011, vol. 58, núm. 12, p. 3376-3385.
Títol: Novel estimation of the electrical bioimpedance using the local polynomial method. Application to in vivo real-time myocardium tissue impedance characterization during the cardiac cycle
Autor: Sánchez Terrones, Benjamín Veure Producció científica UPC; Schoukens, J.; Bragós Bardia, Ramon Veure Producció científica UPC; Vandersteen, G.
Data: 18-nov-2011
Tipus de document: Article
Resum: Classicalmeasurements ofmyocardium tissue electrical impedance for characterizing the morphology of myocardium cells, as well as cell membranes integrity and intra/extra cellular spaces, are based on the frequency-sweep electrical impedance spectroscopy (EIS) technique. In contrast to the frequency-sweep EIS approach, measuring with broadband signals, i.e., multisine excitations, enables to collect, simultaneously, multiple myocardium tissue impedance data in a short measuring time. However, reducing the measuring time makes the measurements to be prone to the influence of the transients introduced by noise and the dynamic time-varying properties of tissue. This paper presents a novel approach for the impedance-frequency-response estimation based on the local polynomial method (LPM). The fast LPM version presented rejects the leakage error’s influence on the impedance frequency response when measuring electrical bioimpedance in a short time. The theory is supported by a set of validation measurements. Novel preliminary experimental results obtained from real-time in vivo healthy myocardium tissue impedance characterization within the cardiac cycle using multisine excitation are reported.
ISSN: 0018-9294
URI: http://hdl.handle.net/2117/16062
DOI: 10.1109/TBME.2011.2166116
Versió de l'editor: http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5999711&tag=1
Apareix a les col·leccions:Altres. Enviament des de DRAC
IEB - Instrumentació Electrònica i Biomèdica. Articles de revista
Departament d'Enginyeria Electrònica. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius