DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/15810

Arxiu Descripció MidaFormat
245-1918-3-PB.pdf2.88 MBAdobe PDFThumbnail
Veure/Obrir

Citació: de Figueiredo, A.D. [et al.]. Steel fiber reinforced concrete pipes. Part 1: technological analysis of the mechanical behavior. "IBRACON structures and materials journal", Gener 2012, vol. 5, núm. 1, p. 1-11.
Títol: Steel fiber reinforced concrete pipes. Part 1: technological analysis of the mechanical behavior
Autor: Domingues de Figueiredo, Antonio; Fuente Antequera, Albert de la Veure Producció científica UPC; Aguado de Cea, Antonio Veure Producció científica UPC; Molins i Borrell, Climent Veure Producció científica UPC; Chama Neto, Pedro Jorge
Data: gen-2012
Tipus de document: Article
Resum: This paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part (“Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test”), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.
ISSN: 1983-4195
URI: http://hdl.handle.net/2117/15810
Versió de l'editor: http://www.revistas.ibracon.org.br/index.php/riem/article/view/245/255
Apareix a les col·leccions:DEC - Departament d'Enginyeria de la Construcció. Articles de revista
TE - Tecnologia d´Estructures. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).

Per a qualsevol ús que es vulgui fer diferent al permès, dirigiu-vos a: sepi@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius