DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/15167

Ítem no disponible en accés obert per política de l'editorial

Arxiu Descripció MidaFormat
06022781.pdf1,73 MBAdobe PDF Accés restringit

Citació: Senturk, O. [et al.]. Converter structure-based power loss and static thermal modeling of the press-pack IGBT three-level ANPC VSC applied to multi-MW wind turbines. "IEEE transactions on industry applications", 19 Setembre 2011, vol. 47, núm. 6, p. 2505-2515.
Títol: Converter structure-based power loss and static thermal modeling of the press-pack IGBT three-level ANPC VSC applied to multi-MW wind turbines
Autor: Senturk, Osman S.; Helle, Lars; Munk-Nielsen, Stig; Rodríguez Cortés, Pedro Veure Producció científica UPC; Teodorescu, Remus
Data: 19-set-2011
Tipus de document: Article
Resum: Wind turbine converters demand high power density due to nacelle space limitation and high reliability due to high maintenance cost. Depending on the converter structure, the converter thermal performance determines the converter power density and reliability. To estimate the converter thermal performance, the converter structure-based power loss and thermal models are developed in this study for the medium-voltage (MV) three-level active neutral-point-clamped voltage source converter (3L-ANPC-VSC) utilizing 4500 V-1800 A press-pack insulated-gate bipolar transistor-diode pairs and interfacing a 6 MW wind turbine to a MV grid. The switching power loss models are built using the experimental switching power loss data acquired via the double-pulse tests conducted on a full-scale 3L-ANPC-VSC prototype. The converter static thermal model is developed based on the double-sided water-cooled press-pack switches. Via a single-phase test setup with two full-scale 3L-ANPC-VSC legs, the developed power loss and thermal models are validated experimentally. Employing the validated models, the 3L-ANPC-VSC's thermal performance is demonstrated on simulation for a 6 MW wind turbine grid interface. Hence, these converter structure-based models developed and validated in this study are proven to be suitable for the converter power density and reliability studies based on converter thermal performance.
ISSN: 0093-9994
URI: http://hdl.handle.net/2117/15167
DOI: 10.1109/TIA.2011.2168557
Versió de l'editor: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6022781
Apareix a les col·leccions:Altres. Enviament des de DRAC
SEER - Sistemes Elèctrics d'Energia Renovable. Articles de revista
Departament d'Enginyeria Elèctrica. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius