Citació: Abengózar, A. [et al.]. Contact lens case cleaning procedures affect storage solution pH and osmolality. "Optometry and vision science", Desembre 2011, vol. 88, núm. 12, p. 1414-1421.
Títol: Contact lens case cleaning procedures affect storage solution pH and osmolality
Autor: Abengózar Vela, A.; Pinto Fraga, F. José; González Méijome, J. Manuel; Rallo Capdevila, Miguel Veure Producció científica UPC; Serés Revés, Carmen Veure Producció científica UPC; Calonge Cano, Margarita; González-García, María J.
Data: des-2011
Tipus de document: Article
Resum: AB Purpose. To investigate pH and osmolality changes in the solutions stored in contact lens (CL) cases, when different case rinsing and drying methods are used on a daily basis. Methods. Four multipurpose solutions (Opti-Free Express, Solo-Care Aqua, Re-Nu Multiplus, and Complete) and two hydrogen peroxide systems (AOsept and Oxysept) were studied. Cases were filled with the solutions and kept sealed. After 8 h, the cases underwent different rinsing (rinsing; non-rinsing) and drying (air drying-AD; lint-free tissue drying-LFTD; non-drying-ND) procedures on a daily basis. Five cases of each rinsing/drying combination for each solution were evaluated. The pH and osmolality of the case-contained solution were evaluated on the 1st, 7th, 15th, and then, 30th day. Results. pH and osmolality increased significantly from day 1 to 30, except for Complete in which a significant decrease in pH was found. Rinsing vs. non-rinsing CL cases did not have any influence on the pH or osmolality, except for Oxysept, which showed a significantly higher osmolality value when cases were not rinsed. However, the drying procedure did influence both measurements; pH was significantly higher in the AD compared with the ND group (p < 0.05), and there was a significant difference in osmolality between the three drying conditions (p < 0.05), with the AD group showing the highest values, and the LFTD group showing the lowest. Conclusions. Osmolality and pH values are time and drying process-dependent in a CL case cleaning schedule. Regarding drying conditions, LFTD causes less increase in osmolality. Future studies should determine whether these changes might affect bacterial growth, lens parameters, or subject comfort during CL wear. (C) 2011 American Academy of Optometry
ISSN: 1040-5488
URI: http://hdl.handle.net/2117/14942
DOI: 10.1097/OPX.0b013e318230375f
Apareix a les col·leccions:Altres. Enviament des de DRAC
GOAPI - Grup d´Òptica Aplicada i Processament d´Imatge. Articles de revista
GRCUV - Grup de Recerca del Centre Universitari de la Visió. Articles de revista
Departament d'Òptica i Optometria. Articles de revista
Departaments de Matemàtica Aplicada. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius