Citació: Morgenstern de Muller, C. [et al.]. Comparison of upper airway respiratory resistance measurements with the esophageal pressure/airflow relationship during sleep. A: IEEE Engineering in Medicine and Biology Society. "Proceedings of the 33rd Annual International Conference of the IEEE EMBS". Boston: 2011, p. 3205-3208.
Títol: Comparison of upper airway respiratory resistance measurements with the esophageal pressure/airflow relationship during sleep
Autor: Morgenstern de Muller, Christian Rudolf Veure Producció científica UPC; Schwaibold, Matthias; Randerath, W.; Bolz, Armin; Jané Campos, Raimon Veure Producció científica UPC
Data: 2011
Tipus de document: Conference report
Resum: Measurement of upper airway resistance is of interest in sleep disordered breathing to estimate upper airway patency. Resistance is calculated with the airflow and respiratory effort signals. However, there is no consensus on a standard for upper airway resistance measurement. This study proposes a new benchmarking method to objectively compare different upper airway resistance measurement methods by objectively differentiating between breaths with inspiratory flow limitation (high resistance) and non-limited breaths (low resistance). Resistance was measured at peak-Pes, at peak-flow, at the linear portion of a polynomial equation, as an area comparative and as average resistance for an inspiration. A total of 20 patients with systematic, gold-standard esophageal pressure and nasal airflow acquisition were analyzed and 109,955 breaths were automatically extracted and evaluated. Relative resistance values in relationship to a reference resistance value obtained during wakefulness were also analyzed. The peak-Pes measurement method obtained the highest separation index with significant (p < 0.001) differences to the other methods, followed by the area comparative and the peak-flow methods. As expected, average resistances were significantly (p < 0.001) lower for the non-IFL than for the IFL group. Hence, we recommend employing the peak-Pes for accurate upper airway resistance estimation.
ISBN: 978-1-4244-4122-8
URI: http://hdl.handle.net/2117/14469
DOI: 10.1109/IEMBS.2011.6090872
Apareix a les col·leccions:Altres. Enviament des de DRAC
SISBIO - Senyals i Sistemes Biomèdics. Ponències/Comunicacions de congressos
Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial. Ponències/Comunicacions de congressos
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius