| Combining physical-based models ....pdf | | 732.92 kB | Adobe PDF |  |
|
| Citació: | Pedretti, D. [et al.]. Combining physical-based models and satellite images for the spatio-temporal assessment of soil infiltration capacity. "Stochastic environmental research and risk assessment", 29 Maig 2011, vol. 25, núm. 8, p. 1065-1075. |
| Títol: | Combining physical-based models and satellite images for the spatio-temporal assessment of soil infiltration capacity |
| Autor: | Pedretti, Daniele ; Fernández García, Daniel ; Sánchez Vila, Francisco Javier ; Barahona-Palomo, Marco ; Bolster, Diogo  |
| Data: | 29-mai-2011 |
| Tipus de document: | Article |
| Resum: | The performance of managed artificial recharge (MAR) facilities by means of surface ponds (SP) is controlled by the temporal evolution of the global infiltration
capacity Ic of topsoils. Cost-effective maintenance operations that aim to maintain controlled infiltration values during the activity of the SP require the full knowledge of the spatio-temporal variability of Ic. This task is deemed uncertain. The natural reduction in time of Ic depends on
complex physical, biological and chemical reactions that clog the soil pores and has been observed to decay exponentially to an asymptotic non-zero value. Moreover, the
relative influence of single clogging processes depend on some initial parameters of the soil, such as the initial infiltration capacity (Ic,0). This property is also uncertain, as aquifers are typically heterogeneous and scarcely characterized in practical situations. We suggest a method to
obtain maps of Ic using a geostatistical approach, which is suitable to be extended to engineering risk assessment concerning management of SP facilities. We propose to
combine geostatistical inference and a temporally-lumped physical model to reproduce non-uniform clogging in topsoils of a SP, using field campaigns of local and large scale tests and additionally by means of satellite images as secondary information. We then postulate a power-law
relationship between the parameter of the exponential law, k, and Ic,0. It is found that calibrating the two parameters of the power law model it is possible to fit the temporal evolution of total infiltration rate at the pond scale in a MAR test facility. The results can be used to design
appropriate measures to selectively limit clogging during operation, extending the life of the infiltration pond. |
| ISSN: | 1436-3240 |
| URI: | http://hdl.handle.net/2117/14221 |
| Versió de l'editor: | 10.1007/s00477-011-0486-4 |
| Versió de l'editor: | http://www.springerlink.com/content/x8j4g36117687422/ |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC ETCG – Departament d’Enginyeria del Terreny, Cartogràfica i Geofísica. Articles de revista GHS - Grup d'Hidrologia Subterrània. Articles de revista
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).