DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/13718

Ítem no disponible en accés obert per política de l'editorial

Arxiu Descripció MidaFormat
IFMBE-2009_doi_Tidal_Volume_Balleza.pdfPDF de la pàgina d'Springer amb el DOI94,22 kBAdobe PDF Accés restringit
Balleza_Tidal Volume_IFMBE 2009.pdf181,75 kBAdobe PDF Accés restringit

Citació: Balleza, M.; Casan, P.; Riu, P. Tidal volume monitoring with electrical impedance tomography (EIT) on COPD patients : relationship between EIT and diffusion lung transfer (DL,CO). A: World Congress on Medical Physics and Biomedical Engineering. "IFMBE 2009 World Congress on Medical Physics and Biomedical Engineering". Munich: Springer Verlag, 2009, p. 549-552.
Títol: Tidal volume monitoring with electrical impedance tomography (EIT) on COPD patients : relationship between EIT and diffusion lung transfer (DL,CO)
Autor: Balleza, Marco; Casan, P.; Riu Costa, Pere Joan Veure Producció científica UPC
Editorial: Springer Verlag
Data: set-2009
Tipus de document: Conference report
Resum: Equations used to estimate ventilation out of EIT images, validated on healthy volunteers show a significant bias and a larger variance when applied to COPD patients. The differences in estimation values were found to be highly correlated to anthropometric parameters and CO exchange (DL,CO) in a previous group of COPD patients. A new group of 13 COPD male patients (FEV1/FVC<70% and FVC ≥ 80%) was used in this study, with stricter inclusion criteria than in the previous one. Anthropometric parameters (age, weight, height, skinfolds) and values of several pulmonary function tests, such as spirometry (FVC, FEV1 and FEV1/FVC), static volumes (RV and TLC) and pulmonary diffusion (DL,CO and DL,CO /VA) were recorded. The EIT system (TIE4sys) and a pneumotach were simultaneously connected to monitor tidal volume. The anthropometric main values of COPD patients were: Age 67±9 years; height 1.65±0.05 m; weight 72±11 kg; BMI 26.4±3.3 kg/m2; Subscapular skinfold 23±9 mm. The mean values of pulmonary function test were: Spyrometry FVC 83±13, FEV1 47±15% of reference value and FEV1/FVC 40±9%. Static Volume test RV 168±43% and TLC 119±12% of reference value. Pulmonary diffusion test DL,CO 56±15%, DL,CO,ADJ 57±15% and DL,CO /VA 68±13% of reference value. The mean tidal volumes estimated with TIE4sys and the pneumotach were: 0.544±0.196 L and 0.763±0.168 L r = 0.861 (p<0.01). The mean difference was 0.218±0.100 L (p<0.01). The differences show a strong correlation with the subscapular and rear skinfold; and the pulmonary diffusion values. The correction equation was: Difference=0.09-0.005 ⋆ (DL,CO,ADJ) +0.028 ⋆ (rear_skinfold)-0.01 ⋆ (subscapular skinfold) (R2=0.899; p<0.01). The differences of determinations estimated with pneumotach and TIE4sys can be attributed to changes in lung internal anatomy (DL,CO, DL,CO,adj Hb, DL,CO/VA) and also anthropometric characteristics like subscapular skinfold.
ISBN: 978-3-642-03897-6
URI: http://hdl.handle.net/2117/13718
DOI: 10.1007/978-3-642-03879-2_153
Apareix a les col·leccions:Altres. Enviament des de DRAC
IEB - Instrumentació Electrònica i Biomèdica. Ponències/Comunicacions de congressos
Departament d'Enginyeria Electrònica. Ponències/Comunicacions de congressos
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius