Citació: Scharfetter, H; Casañas, R; Rosell, J. Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations. IEEE Transactions on Biomedical Engineering, 2003, vol. 50, núm.7 p. 870-880
Títol: Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations
Autor: Scharfetter, Hermann; Casañas Bueno, Roberto Veure Producció científica UPC; Rosell Ferrer, Francisco Javier Veure Producció científica UPC
Editorial: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Data: 31-jul-2003
Tipus de document: Article
Resum: Magnetic induction spectroscopy (MIS) aims at the contactless measurement of the passive electrical properties (PEP) σ, ε, and μ of biological tissues via magnetic fields at multiple frequencies. Whereas previous publications focus on either the conductive or the magnetic aspect of inductive measurements, this article provides a synthesis of both concepts by discussing two different applications with the same measurement system: 1) monitoring of brain edema and 2) the estimation of hepatic iron stores in certain pathologies. We derived the equations to estimate the sensitivity of MIS as a function of the PEP of biological objects. The system requirements and possible systematic errors are analyzed for a MIS-channel using a planar gradiometer (PGRAD) as detector.We studied 4 important error sources: 1) moving conductors near the PGRAD; 2) thermal drifts of the PGRAD-parameters; 3) lateral displacements of the PGRAD; and 4) phase drifts in the receiver. All errors were compared with the desirable resolution. All errors affect the detected imaginary part (mainly related to σ ) of the measured complex field much less than the real part (mainly related to ε and μ). Hence, the presented technique renders possible the resolution of (patho-) physiological changes of the electrical conductivity when applying highly resolving hardware and elaborate signal processing. Changes of the magnetic permeability and permittivity in biological tissues are more complicated to deal with and may require chopping techniques, e.g., periodic movement of the object.
ISSN: 0018-9294
URI: http://hdl.handle.net/2117/1343
Apareix a les col·leccions:IEB - Instrumentació Electrònica i Biomèdica. Articles de revista
Departament d'Enginyeria Electrònica. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius