DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/13273

Ítem no disponible en accés obert per política de l'editorial

Arxiu Descripció MidaFormat
Tarantino - Benchmark of experimental techniques for measuring ....pdf182,97 kBAdobe PDF Accés restringit

Citació: Tarantino, A. [et al.]. Benchmark of experimental techniques for measuring and controlling suction. "Géotechnique", 2011, vol. 61, núm. 4, p. 303-312.
Títol: Benchmark of experimental techniques for measuring and controlling suction
Autor: Muñoz, Juan Jorge Veure Producció científica UPC; Tarantino, A; Gallipoli, Domenico; Augarde, C. E.; Gennaro, V. de; Gómez, R.; Laloui, L.; Mancuso, C.; El Mountassir, G.; Wheeler, S. J.; Tombolato, S.; Toll, D. G.; Rojas Arias, Juan Carlos; Raveendiraraj, A.; Romero Morales, Enrique Edgar Veure Producció científica UPC; Pisoni, G.; Peron, H.; Pereira, J.-M.
Data: 2011
Tipus de document: Article
Resum: The paper presents a benchmarking study carried out within the ‘Mechanics of Unsaturated Soils for Engineering’ (MUSE) network aimed at comparing different techniques for measurement and control of suction. Techniques tested by the eight ‘Mechanics of Unsaturated Soils for Engineering’ research teams include axis-translation (pressure plate and suction-controlled oedometer), highcapacity tensiometer and osmotic technique. The soil used in the exercise was a mixture of uniform sand, sodium bentonite (active clay) and kaolinite (non-active clay), which were all commercially available. Samples were prepared by one team and distributed to all other teams. They were normally consolidated from slurry under one-dimensional conditions (consolidometer) to a given vertical stress. The water retention characteristics of the initially saturated specimens were investigated along the main drying path. Specimens were de-saturated by applying suction through the liquid phase when using an axis-translation technique or osmotic method and de-saturated by air-drying, when suction was measured using igh-capacity tensiometers. In general, the same technique was tested by at least two teams. The water retention curves obtained using the different techniques are compared and discrepancies are discussed in the paper.
ISSN: 0016-8505
URI: http://hdl.handle.net/2117/13273
DOI: 10.1680/geot.2011.61.4.303
Versió de l'editor: http://www.icevirtuallibrary.com/content/article/10.1680/geot.2011.61.4.303
Apareix a les col·leccions:MSR - Mecànica del Sòls i de les Roques. Articles de revista
Altres. Enviament des de DRAC
ETCG – Departament d’Enginyeria del Terreny, Cartogràfica i Geofísica. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius