DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/13108

Ítem no disponible en accés obert per política de l'editorial

Arxiu Descripció MidaFormat
Air infiltration in Catalan dwellings....pdf343,28 kBAdobe PDF Accés restringit

Citació: Montoya, M.I.; Pastor, E.; Planas, E. Air infiltration in Catalan dwellings and sealed rooms: An experimental study. "Building and environment", Octubre 2011, vol. 46, núm. 10, p. 2003-2011.
Títol: Air infiltration in Catalan dwellings and sealed rooms: An experimental study
Autor: Montoya Rodríguez, María Isabel Veure Producció científica UPC; Pastor Ferrer, Elsa Veure Producció científica UPC; Planas Cuchi, Eulàlia Veure Producció científica UPC
Data: oct-2011
Tipus de document: Article
Resum: In this study, we performed a series of trials to measure the infiltration air exchange rate (ACH) of several single-family dwellings throughout Catalonia, as well as the ACH of sealed rooms that could be used as indoor shelters. A shelter is an indoor room where people can take protection in case of a toxic gas release, while the toxic cloud passes through the dwelling. Experimental measurements were made using the tracer gas decay technique with CO2 as the tracer gas in 2 periodsdsummer and winterdwith the aim of characterizing air infiltration in Catalan dwellings. The geometric means obtained for the ACH of shelters and dwellings were 0.16 and 0.23 h-1, respectively, that is, lower than those reported for North American (0.56 h-1) and Greek (0.76 h-1) dwellings. In general, the ACH was lower for shelters than for dwellings, and the average reduction btained in shelters with respect to dwellings was 35%. The largest reductions were obtained in old dwellings with small floor areas and few stories. As for meteorological conditions, we found that the ACH of dwellings was more closely linked to wind speed than indoore-outdoor temperature difference, while the ACH of shelters was more affected by indoore-outdoor temperature and temperature differences inside the dwelling, particularly in dwellings with 3 or more stories.
ISSN: 0360-1323
URI: http://hdl.handle.net/2117/13108
DOI: 10.1016/j.buildenv.2011.04.009
Apareix a les col·leccions:Altres. Enviament des de DRAC
CERTEC - Centre d´Estudis del Risc Tecnològic. Articles de revista
Departament d'Enginyeria Química. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius