| Air infiltration in Catalan dwellings....pdf | | 343.28 kB | Adobe PDF |  |
|
| Citació: | Montoya, M.I.; Pastor, E.; Planas, E. Air infiltration in Catalan dwellings and sealed rooms: An experimental study. "Building and environment", Octubre 2011, vol. 46, núm. 10, p. 2003-2011. |
| Títol: | Air infiltration in Catalan dwellings and sealed rooms: An experimental study |
| Autor: | Montoya Rodríguez, María Isabel ; Pastor Ferrer, Elsa ; Planas Cuchi, Eulàlia  |
| Data: | oct-2011 |
| Tipus de document: | Article |
| Resum: | In this study, we performed a series of trials to measure the infiltration air exchange rate (ACH) of several
single-family dwellings throughout Catalonia, as well as the ACH of sealed rooms that could be used as indoor shelters. A shelter is an indoor room where people can take protection in case of a toxic gas
release, while the toxic cloud passes through the dwelling. Experimental measurements were made using the tracer gas decay technique with CO2 as the tracer gas in 2 periodsdsummer and winterdwith the aim of characterizing air infiltration in Catalan dwellings. The geometric means obtained for the ACH of shelters and dwellings were 0.16 and 0.23 h-1, respectively, that is, lower than those reported for North American (0.56 h-1) and Greek (0.76 h-1) dwellings. In general, the ACH was lower for shelters than for dwellings, and the average reduction btained in shelters with respect to dwellings was 35%. The largest reductions were obtained in old dwellings with small floor areas and few stories. As for meteorological conditions, we found that the ACH of dwellings was more closely linked to wind speed than indoore-outdoor temperature difference, while the ACH of shelters was more affected by indoore-outdoor temperature and temperature differences inside the dwelling, particularly in dwellings with 3 or more
stories. |
| ISSN: | 0360-1323 |
| URI: | http://hdl.handle.net/2117/13108 |
| Versió de l'editor: | 10.1016/j.buildenv.2011.04.009 |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC Departament d'Enginyeria Química. Articles de revista CERTEC - Centre d´Estudis del Risc Tecnològic. Articles de revista
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).