|
E-prints UPC >
Altres >
Enviament des de DRAC >
Empreu aquest identificador per citar o enllaçar aquest ítem:
http://hdl.handle.net/2117/12710
|
Ítem no disponible en accés obert per política de l'editorial
| Arxiu |
Descripció |
Mida | Format |
| Sensor materials for the detection of human neutrophil....pdf | | 255.44 kB | Adobe PDF |  |
|
| Citació: | Hasmann, A. [et al.]. Sensor materials for the detection of human neutrophil elastase and cathepsin G activity in wound ¿uid. "Experimental dermatology", 13 Abril 2011, vol. 20, núm. 6, p. 508-511. |
| Títol: | Sensor materials for the detection of human neutrophil elastase and cathepsin G activity in wound ¿uid |
| Autor: | Wehrschuetz-Sigl, Eva; Guebitz, George M.; Van der Palen, Job; Hasmann, Andrea; Gewessler, Ulrike; Hulla, Elisabet; Schneider, Konstantin P.; Binder, Barbara; Francesko, Antonio ; Tzanov, Tzanko ; Schintler, Michael |
| Data: | 13-abr-2011 |
| Tipus de document: | Article |
| Resum: | Human neutrophil elastase (HNE) and cathepsin G (CatG) are involved in the pathogenesis of a number of inflammatory disorders. These serine proteinases are released by neutrophils and monocytes in case of infection. Wound infection is a severe complication regarding wound healing causing diagnostic and therapeutic problems. In this study we have shown the potential of HNE and CatG to be used as markers for early detection of infection. Significant differences in HNE and CatG levels in infected and non-infected wound fluids were observed. Peptide substrates for these two enzymes were successfully immobilised on different surfaces, including collagen, modified collagen, polyamide polyesters and silica gel. HNE and CatG activities were monitored directly in wound fluid via hydrolysis of the chromogenic substrates. Infected wound fluids led to significant higher substrate hydrolysis compared with non-infected ones. These different approaches could be used for the development of devices which are able to detect elevated enzyme activities before manifestation of infection directly on bandages. This would allow a timely intervention by medical doctors thus preventing severe infections. |
| ISSN: | 0906-6705 |
| URI: | http://hdl.handle.net/2117/12710 |
| Versió de l'editor: | 10.1111/j.1600-0625.2011.01256.x |
| Versió de l'editor: | www.blackwellpublishing.com/EXD |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC Departament d'Enginyeria Química. Articles de revista GBMI - Grup de Biotecnologia Molecular i Industrial. Articles de revista
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).
Per a qualsevol ús que es vulgui fer diferent al permès, dirigiu-vos a: sepi@upc.edu
|