DSpace DSpace UPC
 Català   Castellano   English  

E-prints UPC >
Altres >
Enviament des de DRAC >

Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/2117/12522

Ítem no disponible en accés obert per política de l'editorial

Arxiu Descripció MidaFormat
05627570.pdf444,69 kBAdobe PDF Accés restringit

Citació: Sarlabous, L. [et al.]. Interpretation of the approximate entropy using fixed tolerance values as a measure of amplitude variations in biomedical signals. A: Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). "32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS) :". Buenos Aires: IEEE Press. Institute of Electrical and Electronics Engineers, 2010, p. 5967-5970.
Títol: Interpretation of the approximate entropy using fixed tolerance values as a measure of amplitude variations in biomedical signals
Autor: Sarlabous Uranga, Leonardo Veure Producció científica UPC; Torres Cebrián, Abel Veure Producció científica UPC; Fiz Fernández, José Antonio; Gea Guiral, Joaquim; Martínez Llorens, Juana María; Morera Prat, Josep Maria Veure Producció científica UPC; Jané Campos, Raimon Veure Producció científica UPC
Editorial: IEEE Press. Institute of Electrical and Electronics Engineers
Data: 2010
Tipus de document: Conference report
Resum: A new method for the quantification of amplitude variations in biomedical signals through moving approximate entropy is presented. Unlike the usual method to calculate the approximate entropy (ApEn), in which the tolerance value (r) varies based on the standard deviation of each moving window, in this work ApEn has been computed using a fixed value of r. We called this method, moving approximate entropy with fixed tolerance values: ApEnf. The obtained results indicate that ApEnf allows determining amplitude variations in biomedical data series. These amplitude variations are better determined when intermediate values of tolerance are used. The study performed in diaphragmatic mechanomyographic signals shows that the ApEnf curve is more correlated with the respiratory effort than the standard RMS amplitude parameter. Furthermore, it has been observed that the ApEnf parameter is less affected by the existence of impulsive, sinusoidal, constant and Gaussian noises in comparison with the RMS amplitude parameter.
ISBN: 978-1-4244-4123-5
URI: http://hdl.handle.net/2117/12522
DOI: 10.1109/IEMBS.2010.5627570
Apareix a les col·leccions:Altres. Enviament des de DRAC
SISBIO - Senyals i Sistemes Biomèdics. Ponències/Comunicacions de congressos
Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial. Ponències/Comunicacions de congressos
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius