| Citació: | Sarlabous, L. [et al.]. Interpretation of the approximate entropy using fixed tolerance values as a measure of amplitude variations in biomedical signals. A: Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). "32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS) :". Buenos Aires: IEEE Press. Institute of Electrical and Electronics Engineers, 2010, p. 5967-5970. |
| Títol: | Interpretation of the approximate entropy using fixed tolerance values as a measure of amplitude variations in biomedical signals |
| Autor: | Sarlabous Uranga, Leonardo ; Torres Cebrián, Abel ; Fiz Fernández, José Antonio; Gea Guiral, Joaquim; Martínez Llorens, Juana María; Morera Prat, Josep Maria ; Jané Campos, Raimon  |
| Editorial: | IEEE Press. Institute of Electrical and Electronics Engineers |
| Data: | 2010 |
| Tipus de document: | Conference report |
| Resum: | A new method for the quantification of amplitude
variations in biomedical signals through moving approximate
entropy is presented. Unlike the usual method to calculate the
approximate entropy (ApEn), in which the tolerance value (r)
varies based on the standard deviation of each moving window,
in this work ApEn has been computed using a fixed value of r.
We called this method, moving approximate entropy with fixed
tolerance values: ApEnf. The obtained results indicate that
ApEnf allows determining amplitude variations in biomedical
data series. These amplitude variations are better determined
when intermediate values of tolerance are used. The study
performed in diaphragmatic mechanomyographic signals
shows that the ApEnf curve is more correlated with the
respiratory effort than the standard RMS amplitude
parameter. Furthermore, it has been observed that the ApEnf
parameter is less affected by the existence of impulsive,
sinusoidal, constant and Gaussian noises in comparison with
the RMS amplitude parameter. |
| ISBN: | 978-1-4244-4123-5 |
| URI: | http://hdl.handle.net/2117/12522 |
| Versió de l'editor: | 10.1109/IEMBS.2010.5627570 |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial. Ponències/Comunicacions de congressos SISBIO - Senyals i Sistemes Biomèdics. Ponències/Comunicacions de congressos
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).
Per a qualsevol ús que es vulgui fer diferent al permès, dirigiu-vos a: sepi@upc.edu
|