Citació: Giovinazzo, G. [et al.]. Transoesophageal electrical bioimpedance measurements of the heart in humans. A: World Congress on Medical Physics and Biomedical Engineering. "IFMBE 2009 World Congress on Medical Physics and Biomedical Engineering". Munich: Springer Verlag, 2009, p. 141-144.
Títol: Transoesophageal electrical bioimpedance measurements of the heart in humans
Autor: Giovinazzo, Giuseppe Veure Producció científica UPC; Raga, S.; Ribas, N.; Bayés-Genís, Antoni; Cinca, J.; Rosell Ferrer, Francisco Javier Veure Producció científica UPC
Editorial: Springer Verlag
Data: set-2009
Tipus de document: Conference report
Resum: Previous studies have proved that posttransplant cardiac rejection is associated with changes in endomyocardial electrical impedance in humans. The aim of this study is to develop a safe transoesophageal system able to measure cardiac electrical impedance in transplanted patients and to evaluate the capability of this technique to detect heart graft rejection in humans in order to reduce the number of repetitive biopsies. The impedance measurement is performed using a four wire configuration. We measured the impedance spectrum from 13 kHz to 1 MHz. The oesophageal ECG signal is used to evaluate the position of the catheter in the oesophagus with regard to the patient’s heart. So far measurements have been carried out on a group composed of 11 healthy volunteers (5 men) and 9 cardiac transplanted patients (7 men) with no histological signs of cardiac rejection. Impedance spectrum measurements at different locations in the oesophagus showed a decrease of the impedance magnitude with the increase of the depth of the catheter in the oesophagus (about 1 ohm/cm). The phase value does not show significant changes when changing the catheter’s position in the oesophagus. There are gender differences in the magnitude but not in the phase angle of the transoesophageal cardiac electrical impedance. Transplanted patients with no graft rejection show impedance values similar to that of healthy volunteers, suggesting that the surgical intervention does not affect the impedance measures. The oesophageal approach is safe and was considered for transplanted patients less annoying than the biopsy method. In consequence, if further results show a significant change of impedance in patients with cardiac rejection, a new lessinvasive clinical method to detect graft rejection can be envisaged.
ISBN: 978-3-642-03897-6
URI: http://hdl.handle.net/2117/11970
Versió de l'editor: http://www.wc2009.org/WORLD-CONGRESS-2009/IFMBE/Pages/default.aspx
Apareix a les col·leccions:Altres. Enviament des de DRAC
IEB - Instrumentació Electrònica i Biomèdica. Ponències/Comunicacions de congressos
Departament d'Enginyeria Electrònica. Ponències/Comunicacions de congressos
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius