E-prints UPC >
Altres >
Enviament des de DRAC >
Empreu aquest identificador per citar o enllaçar aquest ítem:
http://hdl.handle.net/2117/11775
|
| Citació: | Escalas, A. [o Escalas-Cañellas, A.]; Ortiz-Balderas, M.A.; Barajas-López, M.G. Evaluation of modifications to a physicochemical method for determination of readily biodegradable COD. "Water SA", Octubre 2009, vol. 35, núm. 5, p. 567-578. |
| Títol: | Evaluation of modifications to a physicochemical method for determination of readily biodegradable COD |
| Autor: | Escalas Cañellas, Antoni ; Ortiz Balderas, María de los Ángeles ; Barajas López, María Guadalupe |
| Data: | oct-2009 |
| Tipus de document: | Article |
| Resum: | In the Mamais-Jenkins-Pitt method for determination of readily biodegradable COD (SS), 2 alternatives were proposed for the intermediate determination of soluble inert COD (SI). When a full-scale treatment plant exists, influent SI = effluent truly soluble COD. When there is no full-scale plant, then the truly soluble COD of the effluent of a 24 h fill-and-draw batch reactor treating the wastewater is taken as influent SI.
In this study, both SI methods were statistically compared on 24 wastewater samples from 2 municipal wastewater treatment plants (WWTPs). While average SI obtained for the 2 methods was the same, individual samples usually had very
different SI values. In fact, virtually no correlation was found between the 2 methods. Also, the SS values obtained using both SI alternatives were statistically compared. A good correlation was observed, in spite of the poor SI correlation – low, dispersed SI values did not seriously affect the correlation between both SS determinations. A method was proposed for determination of the limit of detection and the limit of quantification (LOQ) for both SS methods. The LOQ resulted in 28.6 mg/l and 32.6 mg/l, respectively, for the full-scale and the laboratory-scale alternatives.
Some assumptions of the original laboratory-scale (LS) method could potentially be sources of error in SI determination.
Two modifications to the laboratory-scale method were implemented in order to avoid these potential problems:
Washing biomass with tap water, and correcting SI in the fill-and-draw reactor by the SI of the original biomass suspension.
These method modifications were tested on wastewater samples from the mentioned WWTPs. The fundamentals and results of both modifications are discussed in this paper, as well as the imprecision associated with estimating influent SI from effluent CODsol in all studied methods, and its impact on SS determination. |
| ISSN: | 0378-4738 |
| URI: | http://hdl.handle.net/2117/11775 |
| Versió de l'editor: | http://www.ajol.info/index.php/wsa/article/viewFile/49183/35526 |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC Departament d'Enginyeria Química. Articles de revista
|
| Comparteix: |
|
Queda prohibida la reproducció, transformació, distribució i comunicació pública d'aquesta obra. Es permet, en tot cas, la reproducció per a ús privat sempre i quan la còpia que se'n faci no sigui objecte d'utilització col·lectiva ni lucrativa (art. 31.2 del Reial Decret Legislatiu 1/1996, de 12 d'abril, pel qual s'aprova el Text Refós de la Llei de Propietat Intel·lectual, http://bibliotecnica.upc.es/sepi/legislacio.asp).
Per a qualsevol ús que es vulgui fer diferent al permès, dirigiu-vos a: sepi@upc.edu
|