Citació: Palacios, J.; Romeu, J.; Balastegui, A. Two step optimization of transducer locations in single input single output tonal global active noise control in enclosures. "Journal of vibration and acoustics. Transactions of the ASME", Desembre 2010, vol. 132, núm. December, p. 1-8.
Títol: Two step optimization of transducer locations in single input single output tonal global active noise control in enclosures
Autor: Palacios Higueras, José Ignacio Veure Producció científica UPC; Romeu Garbí, Jordi Veure Producció científica UPC; Balastegui Manso, Andreu Veure Producció científica UPC
Data: des-2010
Tipus de document: Article
Resum: Global active control of sound can be achieved inside enclosures under low modal acoustic fields. However, the performance of the system depends largely on the localization of the elements of the control system. For a purely acoustic active control system in which secondary acoustic sources (loudspeakers) and pressure transducers (microphones) as error sensors are used, several optimization strategies have been proposed. These strategies usually rely on partial approximation to the problem, focusing on the study of number and localization of secondary sources without considering error transducers, or selecting the best positions of secondary sources and error transducers of an initial set of candidate locations for these elements. The strategy presented here for tonal global active noise control of steady states comprises two steps; the first is rather common for this sort of problem and its goal is to find the best locations for secondary sources and their strengths by minimizing the potential energy of the enclosure. The second step is the localization of the error transducer, which ensures the results of the first step. It is analytically demonstrated that for a single input single output system, the optimum location of error transducers is at a null pressure point of the optimally attenuated acoustic field. It is also shown that in a real case, the optimum position is that of a minimum of the optimally attenuated acoustic field. Finally, a numerical validation of this principle is carried out in a parallelipedic enclosure.
ISSN: 1048-9002
URI: http://hdl.handle.net/2117/10176
DOI: 10.1115/1.4002122
Versió de l'editor: http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JVACEK000132000006061011000001&idtype=cvips&gifs=yes
Apareix a les col·leccions:LEAM - Laboratori d'Enginyeria Acústica i Mecànica. Articles de revista
Departament d'Enginyeria mecànica. Articles de revista
Altres. Enviament des de DRAC
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets.

Per a qualsevol ús que se'n vulgui fer no previst a la llei, dirigiu-vos a: sepi.bupc@upc.edu

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius