Ara es mostren els items 3-18 de 18

    • Calidad óptica ocular en ojos sometidos a cirugía refractiva y afecciones patológicas 

      Ondategui Parra, Juan Carlos (Universitat Politècnica de Catalunya, 2016-01-29)
      Tesi
      Accés obert
      This dissertation deals with the evaluation of ocular optical quality in two types of patients. First, are patients who have undergone different surgical techniques of refractive surgery to correct different degrees of ...
    • Double-pass technique and compensation-comparison method in eyes with cataract 

      Martínez Roda, Juan Antonio; Vilaseca Ricart, Meritxell; Ondategui Parra, Juan Carlos; Almudí Cortés, Lorena; Asaad Ammaar, Mouafk; Mateos Pena, Lorena; Arjona Carbonell, Mª Montserrat; Pujol Ramo, Jaume (2016-10-30)
      Article
      Accés obert
      PURPOSE To clinically assess the objective scatter index (OSI) obtained from double-pass images and the log(s) parameter measured with the direct compensation-comparison psychophysical technique in eyes with cataract. ...
    • Effects of aging on optical quality and visual function 

      Martínez Roda, Juan Antonio; Vilaseca Ricart, Meritxell; Ondategui Parra, Juan Carlos; Aguirre, Montserrat; Pujol Ramo, Jaume (2016-09-02)
      Article
      Accés obert
      Background: We assessed the effects of aging on visual function and optical quality in a healthy adult population and provide reference values for different age ranges. Methods: We conducted a prospective study with 198 ...
    • Grading nuclear, cortical and posterior subcapsular cataracts using an objective scatter index measured with a double-pass system 

      Vilaseca Ricart, Meritxell; Romero Vallés, M.José; Arjona Carbonell, Mª Montserrat; Luque, Sergio Oscar; Ondategui Parra, Juan Carlos; Salvador Playà, A.; Güell, Jose Luis; Artal, Pablo; Pujol Ramo, Jaume (2012-09)
      Article
      Accés obert
    • Líneas de investigación en óptica visual y tecnología del color en el CD6 

      Pujol Ramo, Jaume; Vilaseca Ricart, Meritxell; Arjona Carbonell, Mª Montserrat; de Lasarte, Marta; Aldaba Arévalo, Mikel; Zuluaga Duque, Harold; Herrera Ramírez, Jorge Alexis; Díaz Douton, Fernando; Luque, Sergio Oscar; Sanabria Ortega, Fernando Guillermo; Ondategui Parra, Juan Carlos (2009)
      Text en actes de congrés
      Accés obert
    • Oftalmopatía en la diabetes mellitus: detección desde la Atención Primaria de salud 

      Sender Palacios, M.J; Vernet Vernet, M.; Maseras Bové, M.; Salvador Playà, A.; Pascual Batlle, L.; Ondategui Parra, Juan Carlos; Jovell Fernández, E. (2011-01)
      Article
      Accés restringit per política de l'editorial
      Objetivo: Conocer la viabilidad de la realización de la exploración oftalmológica básica de la patología ocular del paciente diabético desde el ámbito de la Atención Primaria de Salud (APS). Diseño: Estudio transversal ...
    • Optical quality after myopic photorefractive keratectomy and laser in situ keratomileusis: Comparison using a double-pass system 

      Ondategui Parra, Juan Carlos; Vilaseca Ricart, Meritxell; Arjona Carbonell, Mª Montserrat; Montasell, Ana; Cardona Torradeflot, Genís; Güell, José L.; Pujol Ramo, Jaume (2012)
      Article
      Accés restringit per política de l'editorial
    • OPTOMETRIA I CONTACTOLOGIA CLÍNIQUES (examen 1r quadrimestre, 2n parcial) 

      Ondategui Parra, Juan Carlos (Universitat Politècnica de Catalunya, 2017-01-19)
      Examen
      Accés restringit a la comunitat UPC
    • Optometría : manual de exámenes clínicos 

      Borràs García, M. Rosa; Castañé Farran, Marina; Ondategui Parra, Juan Carlos; Pacheco Cutillas, Mireia; Sánchez Herrero, Eulalia; Varón Puentes, Maria Consuelo (Edicions UPC, 1996)
      Llibre
      Accés restringit a la comunitat UPC
      Este texto de exámenes clínicos optométricos ha sido desarrollado en forma de manual para poder ser consultado de forma rápida y sencilla durante la práctica de la optometría. Asimismo, también puede servir de guía para ...
    • Spherical subjective refraction with a novel 3D virtual reality based system 

      Pujol Ramo, Jaume; Ondategui Parra, Juan Carlos; Badiella, Llorenç; Otero, Carles; Vilaseca Ricart, Meritxell; Aldaba Arévalo, Mikel (Elsevier, 2016-01)
      Article
      Accés obert
    • Suitability of open-field autorefractors as pupillometers and instrument design effects 

      Otero Molins, Carles; Aldaba Arévalo, Mikel; Ferrer Garcia, Oriol; Gascón Ruiz, Andrea; Ondategui Parra, Juan Carlos; Pujol Ramo, Jaume (2017-04-18)
      Article
      Accés obert
      AIM: To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. ...
    • System based on the contrast of Purkinje images to measure corneal and lens scattering 

      Santos Vives, Pau; Martínez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Díaz Douton, Fernando; Cazal, Jorge; Vilaseca Ricart, Meritxell (2018-09)
      Article
      Accés obert
      Current methods to measure intraocular scattering provide information on the total scattered light, which consists of the combined contributions originating from different ocular structures. In this work, we propose a ...
    • System for objective assessment of the accommodation response during subjective refraction 

      García Guerra, Carlos Enrique; Martínez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Turull Mallofré, Aina; Aldaba Arévalo, Mikel; Vilaseca Ricart, Meritxell (Association for Research in Vision and Ophthalmology (ARVO), 2023-05)
      Article
      Accés obert
      Purpose: To evaluate a system based on a Hartmann–Shack wavefront sensor attached to a phoropter that allows the user to obtain real-time information about the refractive state of the eye and the accommodation response ...
    • Trabajos de investigación en óptica visual y tecnología del color en el CD6 

      Pujol Ramo, Jaume; Arjona Carbonell, Mª Montserrat; Vilaseca Ricart, Meritxell; Aldaba Arévalo, Mikel; Díaz Douton, Fernando; Luque, Sergio Oscar; Zuluaga Duque, Harold; Herrera Ramírez, Jorge Alexis; Sanabria Ortega, Fernando Guillermo; Ferrer Serrano, Edgar; Martínez Roda, Juan Antonio; Ondategui Parra, Juan Carlos; Burgos Fernández, Francisco Javier; Giner Tort, Anna; Torrecilla Ribalta, Elena (2012)
      Comunicació de congrés
      Accés obert
    • Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children 

      Bueno Gimeno, Inmaculada; España, Enrique; Gene Sampedro, Andres; Ondategui Parra, Juan Carlos; Zapata Rodriguez, Carlos J. (2018-01-02)
      Article
      Accés obert
      The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate ...
    • Visión binocular : diagnóstico y tratamiento 

      Borràs García, M. Rosa; Ondategui Parra, Juan Carlos; Pacheco Cutillas, Mireia; Varón Puentes, Maria Consuelo; Sánchez Herrero, Eulalia; Gispets Parcerisas, Joan (Edicions UPC, 1996)
      Llibre
      Accés restringit a la comunitat UPC
      Este libro está dirigido a todos los profesionales del campo de la optometría que quieran profundizar en la visión binocular. También está indicado para los alumnos de tercer curso de Optometría, tanto en asignaturas ...