Exploració per autor "Jané Campos, Raimon"
Ara es mostren els items 11-30 de 136
-
Assessment of inspiratory muscle activation using surface diaphragm mechanomyography and crural diaphragm electromyography
Lozano García, Manuel; Sarlabous Uranga, Leonardo; Torres Cebrián, Abel; Jané Campos, Raimon (2018)
Text en actes de congrés
Accés restringit per política de l'editorialThe relationship between surface diaphragm mechanomyography (sMMGdi), as a noninvasive measure of inspiratory muscle mechanical activation, and crural diaphragm electromyography (oesEMGdi), as the invasive gold standard ... -
Assessment of respiratory flow cycle morphology in patients with chronic heart failure
Garde, Ainara; Sornmo, Leif; Laguna Lasaosa, Pablo; Jané Campos, Raimon; Benito Vales, Salvador; Bayés Genis, Antoni; Giraldo Giraldo, Beatriz (2017-02-01)
Article
Accés obertBreathing pattern as periodic breathing (PB) in chronic heart failure (CHF) is associated with poor prognosis and high mortality risk. This work investigates the significance of a number of time domain parameters for ... -
Assessment of respiratory muscle activity with surface electromyographic signals acquired by concentric ring electrodes
Ràfols de Urquía, Magda; Estévez Piorno, Josep; Estrada Petrocelli, Luis; Garcia Casado, Javier; Prats Boluda, Gema; Sarlabous Uranga, Leonardo; Jané Campos, Raimon; Torres Cebrián, Abel (2018)
Comunicació de congrés
Accés restringit per política de l'editorialThe assessment of respiratory muscle activity by surface electromyography (sEMG) is a promising noninvasive technique for the diagnosis and monitoring of chronic obstructive pulmonary disease. The diaphragm is the ... -
Assessment of the non-linear response of the fSampEn on simulated EMG signals
Jané Campos, Raimon; Torres Cebrián, Abel; Lozano García, Manuel; Estrada Petrocelli, Luis Carlos (Institute of Electrical and Electronics Engineers (IEEE), 2021)
Text en actes de congrés
Accés obertFixed sample entropy (fSampEn) is a promising technique for the analysis of respiratory electromyographic (EMG) signals. Its use has shown outperformance of amplitude-based estimators such as the root mean square (RMS) in ... -
Assessment of trunk flexion in arm reaching tasks with electromyography and smartphone accelerometry in healthy human subjects
Castillo Escario, Yolanda; Kumru, Hatice; Valls Solé, Josep; García Alen, Loreto; Vidal Samsó, Joan; Jané Campos, Raimon (Nature, 2021-03-08)
Article
Accés obertTrunk stability is essential to maintain upright posture and support functional movements. In this study, we aimed to characterize the muscle activity and movement patterns of trunk flexion during an arm reaching task in ... -
Automatic differentiation of normal and continuous adventitious respiratory sounds using ensemble empirical mode decomposition and instantaneous frequency
Lozano, Manuel; Fiz Fernández, José Antonio; Jané Campos, Raimon (2016-03-01)
Article
Accés obertDifferentiating normal from adventitious respiratory sounds (RS) is a major challenge in the diagnosis of pulmonary diseases. Particularly, continuous adventitious sounds (CAS) are of clinical interest because they reflect ... -
Automatic differentiation of obstructive and central hypopneas with esophageal pressure measurement during sleep
Morgenstern de Muller, Christian Rudolf; Schwaibold, Matthias; Randerath, Winfried J.; Bolz, Armin; Jané Campos, Raimon (2009)
Text en actes de congrés
Accés obertThe differentiation between obstructive and central respiratory events is one of the most recurrent tasks in the diagnosis of sleep disordered breathing. Esophageal pressure measurement is the gold-standard method to ... -
Automatic event detector from smartphone accelerometry: Pilot mHealth study for obstructive sleep apnea monitoring at home
Ferrer Lluís, Ignasi; Castillo Escario, Yolanda; Montserrat Canal, Josep Maria; Jané Campos, Raimon (Institute of Electrical and Electronics Engineers (IEEE), 2019)
Comunicació de congrés
Accés obertObstructive sleep apnea (OSA) is a common disorder with a low diagnosis ratio, leaving many patients undiagnosed and untreated. In the last decades, accelerometry has been found to be a feasible solution to obtain respiratory ... -
Automatic non-invasive differentiation of obstructive and central hypopneas with nasal airflow compared to esophageal pressure
Morgenstern de Muller, Christian Rudolf; Schwaibold, Matthias; Randerath, Winfried J.; Bolz, Armin; Jané Campos, Raimon (2010)
Text en actes de congrés
Accés obertThe differentiation of obstructive and central respiratory events is a major challenge in the diagnosis of sleep disordered breathing. Esophageal pressure (Pes) measurement is the gold-standard method to identify these ... -
Automatic silence events detector from smartphone audio signals: a pilot mHealth system for sleep apnea monitoring at home
Castillo Escario, Yolanda; Ferrer Lluís, Ignasi; Montserrat, Josep Maria; Jané Campos, Raimon (Institute of Electrical and Electronics Engineers (IEEE), 2019)
Comunicació de congrés
Accés obertObstructive sleep apnea (OSA) is a prevalent disease, but most patients remain undiagnosed and untreated. Recently, mHealth tools are being proposed to screen OSA patients at home. In this work, we analyzed full-night audio ... -
Breathing pattern characterization in chronic heart failure patients using the respiratory flow signal
Garde Martínez, Ainara; Sörnmo, Leif; Jané Campos, Raimon; Giraldo Giraldo, Beatriz (2010-07-08)
Article
Accés restringit per política de l'editorialThis study proposes a method for the characterization of respiratory patterns in chronic heart failure (CHF) patients with periodic breathing (PB) and nonperiodic breathing (nPB), using the flow signal. Autoregressive ... -
Breathing pattern estimation using wearable bioimpedance for assessing COPD severity
Blanco Almazán, María Dolores; Groenendaal, Willemijn; Lijnen, Lien; Önder, Rana; Smeets, Christophe; Ruttens, David; Catthoor, Francky; Jané Campos, Raimon (2022-09-19)
Article
Accés obertBreathing pattern has been shown to be different in chronic obstructive pulmonary disease (COPD) patients compared to healthy controls during rest and walking. In this study we evaluated respiratory parameters and the ... -
Cancellation of cardiac interference in diaphragm EMG signals using an estimate of ECG reference signal
Torres Cebrián, Abel; Fiz Fernández, José Antonio; Jané Campos, Raimon (2014)
Text en actes de congrés
Accés obertThe analysis of the electromyographic signal of the diaphragm muscle (EMGdi) can provide important information in order to evaluate the respiratory muscular function. However, EMGdi signals are usually contaminated by the ... -
Caracterización y análisis del ECG, la presión sanguínea y el flujo respiratorio en sujetos sanos
Giraldo Giraldo, Beatriz; Calvo, Alejandro; Martínez, Beatriz; Jané Campos, Raimon (EUETIB, 2013-12)
Comunicació de congrés
Accés obertEl estudio del sistema cardiovascular y del sistema respiratorio, así como su interacción, sigue siendo actualmente un importante campo de investigación en la práctica clínica. Una forma de analizar estos sistemas es a ... -
Cardiac comorbidities in COPD patients explained through HRV analysis and respiratory indices
Romero Pérez, Daniel; Blanco Almazán, María Dolores; Groenendaal, Willemijn; Lijnen, Lien; Smeets, Christophe; Ruttens, David; Catthoor, Francky; Jané Campos, Raimon (2020)
Comunicació de congrés
Accés obertChronic obstructive pulmonary disease (COPD) patients exhibit depressed heart rate variability (HRV), while comorbidities may worsen the patients’ prognosis. We investigated whether HRV analyis, clinical markers of disease ... -
Cardiac interference reduction in diaphragmatic MMG signals during a maintained inspiratory pressure test
Sarlabous Uranga, Leonardo; Torres Cebrián, Abel; Fiz Fernández, José Antonio; Jané Campos, Raimon (Institute of Electrical and Electronics Engineers (IEEE), 2013)
Text en actes de congrés
Accés restringit per política de l'editorialA recursive least square (RLS) adaptive filtering algorithm for reduction of cardiac interference in diaphragmatic mecanomyographic (MMGdi) signals is addressed in this paper. MMGdi signals were acquired with a capacitive ... -
Cardiorespiratory phase synchronization in OSA subjects during wake and sleep states
Solà Soler, Jordi; Giraldo Giraldo, Beatriz; Fiz Fernández, José Antonio; Jané Campos, Raimon (2015)
Text en actes de congrés
Accés restringit per política de l'editorialCardiorespiratory Phase Synchronization (CRPS) is a manifestation of coupling between cardiac and respiratory systems complementary to Respiratory Sinus Arrhythmia. In this work, we investigated CRPS during wake and sleep ... -
Characterization of laplacian surface electromyographic signals during isometric contraction in biceps brachii
Estrada, Luis; Torres Cebrián, Abel; Garcia Casado, Javier; Prats Boluda, Gema; Jané Campos, Raimon (Institute of Electrical and Electronics Engineers (IEEE), 2013)
Text en actes de congrés
Accés restringit per política de l'editorialSurface electromyography (sEMG) is a noninvasive technique for monitoring the electrical activity produced by the muscles. Usually, sEMG is performed by carrying out monopolar or bipolar recordings by means of conventional ... -
Chest movement and respiratory volume both contribute to thoracic bioimpedance during loaded breathing
Blanco Almazán, María Dolores; Groenendaal, Willemijn; Catthoor, Francky; Jané Campos, Raimon (Nature, 2019-12-27)
Article
Accés obertBioimpedance has been widely studied as alternative to respiratory monitoring methods because of its linear relationship with respiratory volume during normal breathing. However, other body tissues and fluids contribute ... -
Clasificación bayesiana de sujetos roncadores con Síndrome de Apnea Hipoapnea del Sueño mediante un método Kernel
Solà Soler, Jordi; Fiz Fernández, José Antonio; Morera Prat, Josep Maria; Jané Campos, Raimon (2011)
Text en actes de congrés
Accés obertEl gold standard para diagnosticar el Síndrome de Apnea Hipoapnea del Sueño (SAHS) es la polisomnografía (PSG), un procedimiento caro y laborioso. Resultaría de mucha ayuda disponer de un método de screening sencillo que ...