    • Effect of wind turbine converter control on wind power plant harmonic response and resonances 

      Sainz Sapera, Luis; Monjo Mur, Lluís; Pedra Durán, Joaquim; Cheah Mañé, Marc; Liang, Jun; Gomis Bellmunt, Oriol (2017-02-01)
      Article
      Accés restringit per política de l'editorial
      Wind turbine harmonic emissions due to power electronics are a well-known power quality concern in wind power plants (WPPs). This problem may be increased by resonances because they amplify harmonic distortion around ...
    • Electrical resonance instability study in traction systems 

      Sainz Sapera, Luis; Monjo Mur, Lluís; Mesas García, Juan José; Pedra Durán, Joaquim; Cheah Mañé, Marc (Institute of Electrical and Electronics Engineers (IEEE), 2016)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      Traction system stability can be affected by the interaction between the traction load and resonances in the railway traction grid. This paper presents an electrical resonance instability study applied to traction systems. ...
    • Electrical resonance instability study in wind power plants 

      Sainz Sapera, Luis; Mesas García, Juan José; Monjo Mur, Lluís; Pedra Durán, Joaquim; Cheah Mañé, Marc (Institute of Electrical and Electronics Engineers (IEEE), 2016)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      Wind power plant stability can be affected by the interaction between the wind turbine and the resonances in the collector grid. This paper presents an electrical resonance instability study applied to wind power plants. The ...
    • Impact of voltage sags on DC bus voltage in unipolar LVDC systems 

      Monjo Mur, Lluís; Mesas García, Juan José; Sainz Sapera, Luis; Saura Perisé, Jaime; Pedra Durán, Joaquim (2015)
      Text en actes de congrés
      Accés obert
    • Initialization of DFIG wind turbines with a phasor-based approach 

      Rolán Blanco, Alejandro; Pedra Durán, Joaquim (2019-03)
      Article
      Accés obert
      The objective of this paper is to propose a simple approach to solve the steady state of a wind turbine (WT) equipped with a doubly-fed induction generator (DFIG) which can be used to initialize dynamic studies of the ...
    • Model of aeronautical ground lighting system transformers 

      lomvarte, daniel; Monjo Mur, Lluís; Sainz Sapera, Luis; Pedra Durán, Joaquim (2015-03-02)
      Article
      Accés obert
      Airport ground lighting (AGL) systems provide visual reference to aircrafts during airport operations. In AGL systems, constant current regulators feed a beacon circuit supplied through isolation transformers. Component ...
    • Model of quasi-Z-source inverter-based PV power systems for stability studies of multi-terminal AC grid-connected PV power systems 

      Monjo Mur, Lluís; Sainz Sapera, Luis; Pedra Durán, Joaquim (Elsevier, 2024-01)
      Article
      Accés obert
      Photovoltaic (PV) power systems are becoming one of the most popular green power systems. Power converters are used in these systems. Among them, quasi-Z-source inverters (qZSIs) are currently on the rise. However, ...
    • On fixed-speed WT generator modeling for rotor speed stability studies 

      Pedra Durán, Joaquim; Córcoles López, Felipe; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago; Rolán Blanco, Alejandro (2012-02)
      Article
      Accés restringit per política de l'editorial
      This paper analyzes fixed-speed induction generator modeling oriented to rotor speed stability studies. The single- and double-cage models are compared. The effects of symmetrical voltage sags on generator behavior are ...
    • Parameter estimation of squirrel-cage motors with parasitic torques in the torque–slip curve 

      Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-04-16)
      Article
      Accés obert
      This paper studies parasitic torques in steady-state torque–slip curves of squirrel-cage induction motors. The curves of nine motors (small, medium and large size units), three of which were measured in the range s = 2 ...
    • Parameter estimation of wound-rotor induction motors from transient measurements 

      Kojooyan, Hengameh; Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2014-06)
      Article
      Accés restringit per política de l'editorial
      A new method for determination of the steady-state equivalent circuit parameters of wound-rotor induction motors using experimental data from starting transient measurements is presented. The algorithm data are the stator ...
    • Quasi-z-source inverter-based photovoltaic power system modeling for grid stability studies 

      Monjo Mur, Lluís; Sainz Sapera, Luis; Mesas García, Juan José; Pedra Durán, Joaquim (2021-01-19)
      Article
      Accés obert
      Quasi-Z-source inverters (qZSIs) are becoming a powerful power conversion technology in photovoltaic (PV) power systems because they allow energy power conversion in a single stage operation. However, they can cause system ...
    • Reduced-order models of squirrel-cage induction generators for fixed-speed wind turbines under unbalanced grid conditions 

      Rolán Blanco, Alejandro; Córcoles López, Felipe; Bogarra Rodríguez, Santiago; Monjo Mur, Lluís; Pedra Durán, Joaquim (2016-06)
      Article
      Accés obert
      This paper develops a study of reduced-order models for squirrel-cage induction generators used in the fixed-speed wind turbines. The squirrel-cage of these generators must be modeled with a double-cage for accuracy purposes. ...
    • Saturation effects on torque- and current–slip curves of squirrel-cage induction motors 

      Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2012-12-24)
      Article
      Accés restringit per política de l'editorial
      This paper measures and analyzes the saturation effects on torque- and current–slip curves of three squirrel-cage induction motors.Motor saturation is illustrated by three sets of measurements: I) torque and current for ...
    • Small synchronous machine protection during voltage sags caused by MV grid faults 

      Bogarra Rodríguez, Santiago; Rubion, X.; Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim; Iglesias, J. (2018-03-01)
      Article
      Accés obert
      This paper analyses the impact of symmetrical and unsymmetrical voltage sags caused by distribution and transmission faults on the dynamic behaviour of small salient-pole synchronous machines connected to the MV grid, and ...
    • Squirrel-cage induction motor parameter estimation using a variable frequency test 

      Monjo Mur, Lluís; Kojooyan, Hengameh; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-06-01)
      Article
      Accés obert
      This paper presents amethod for squirrel-cage induction motor parameter estimation using a phase-to-phase standstill variable frequency test. The measured resistance and reactance at different frequencies are the data of ...
    • State-space model of quasi-z-source inverter-PV systems for transient dynamics studies and network stability assessment 

      Monjo Mur, Lluís; Sainz Sapera, Luis; Mesas García, Juan José; Pedra Durán, Joaquim (2021-07-09)
      Article
      Accés obert
      Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into ...
    • Study of cable short circuit in VSC DC systems 

      Monjo Mur, Lluís; Mesas García, Juan José; Sainz Sapera, Luis; Pedra Durán, Joaquim (2015)
      Text en actes de congrés
      Accés restringit per política de l'editorial
    • Study of MVDC system benchmark networks 

      Mesas García, Juan José; Monjo Mur, Lluís; Sainz Sapera, Luis; Pedra Durán, Joaquim (2015)
      Text en actes de congrés
      Accés restringit per política de l'editorial
    • Study of resonance in wind parks 

      Monjo Mur, Lluís; Sainz Sapera, Luis; Liang, Jun; Pedra Durán, Joaquim (2015-11-01)
      Article
      Accés obert
      Wind turbine harmonic current emissions are a well-known power quality problem. These emissions flow through wind park impedances, leading to grid voltage distortion. Parallel resonance may worsen the problem because it ...
    • Study of the steinmetz circuit influence on AC traction system resonance 

      Sainz Sapera, Luis; Monjo Mur, Lluís; Riera, Sara; Pedra Durán, Joaquim (2012-10-01)
      Article
      Accés restringit per política de l'editorial
      Traction systems are single-phase, nonlinear loads, which can unbalance and pollute supply voltages. To reduce voltage unbalance, reactances are usually connected in delta configuration with traction systems. This setup ...