Exploració per autor "Pallàs-Areny, Ramon"
Ara es mostren els items 66-85 de 127
-
Generar coneixement a la Universitat
Pallàs-Areny, Ramon (Comunicación MetroBCN, 2022-05)
Article de premsa
Accés obertActualment molts joves creuen que la universitat és la continuació de l’institut. Empreses com Google, Facebook, Microsoft, Apple o AstraZeneca demanen doctors/es en ciències o enginyeria -
Heart and respiratory rate detection on a bathroom scale based on the ballistocardiogram and the continuous wavelet transform
Gilaberte Elvira, Sonia; Gómez Clapers, Joan; Casanella Alonso, Ramón; Pallàs-Areny, Ramon (2010)
Text en actes de congrés
Accés restringit per política de l'editorialBallistocardiography is a non-invasive technique that yields information about the cardiovascular system that is not available in other external signals such as the electrocardiogram (ECG). In the last years, several ... -
Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale
Díaz, Delia H.; Casas Piedrafita, Óscar; Pallàs-Areny, Ramon (IEEE Press. Institute of Electrical and Electronics Engineers, 2010)
Text en actes de congrés
Accés restringit per política de l'editorialElectronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart ... -
Impact of the mechanical interface on BCG signals obtained from electronic weighing scales
Casanella Alonso, Ramón; Gómez Clapers, Joan; Hernández Urrea, Marc; Pallàs-Areny, Ramon (2016)
Text en actes de congrés
Accés restringit per política de l'editorialThis work analyzes the reproducibility of the BCG obtained from different weighing scales. First, the natural frequency of three commercial bathroom scales has been characterized by an impulse excitation test. Second, the ... -
La Ingeniería electrónica y la medicina
Pallàs-Areny, Ramon (Escola Tècnica Superior d'Enginyers de Telecomunicació de Barcelona, 1997)
Article
Accés obert -
Interferencias capacitivas en circuitos de interfaz directa entre sensores capacitivos y microcontrolador
Gaitán Pitre, Jorge Eliécer; Pallàs-Areny, Ramon (2012)
Text en actes de congrés
Accés restringit per política de l'editorialSe presenta un análisis experimental del efecto de las interferencias capacitivas en dos circuitos de interfaz directa entre sensores capacitivos y microcontrolador, uno basado en la transferencia de carga (CT, charge ... -
Journal of Electrical Bioimpedance
Pallàs-Areny, Ramon (University of Oslo, 2018-07-30)
Article
Accés obert -
Low-cost method to estimate body capacitance to ground at mid frequencies
Aliau Bonet, Carles; Pallàs-Areny, Ramon (2014)
Text en actes de congrés
Accés restringit per política de l'editorialImpedance measurements that involve the human body are affected by the capacitance between the body and earth ground. This paper describes a low-cost method to estimate that capacitance that can be applied to impedance ... -
Measurement of three independent components in impedance sensors using a single square wave
Lario García, Javier; Pallàs-Areny, Ramon (Elsevier, 2003-12-17)
Article
Accés obertTwo-wire impedance-based sensors involving electrolytes add the impedance of the electrodes to the electrical impedance of the medium to measure. An equivalent circuit for the measured impedance is a resistance in series ... -
Method and apparatus for obtaining cardiovascular information by measuring between two extremities
Pallàs-Areny, Ramon; Casanella Alonso, Ramón; Gómez Clapers, Joan (2014-06-04)
Report de recerca
Accés obertIn this patent of invention there are described a method and an apparatus for obtaining information on the cardiovascular system beat by beat and continuously which are based exclusively on measurements between two limbs ... -
Microphonics in biopotential measurements with capacitive electrodes
Luna Lozano, P. S.; Pallàs-Areny, Ramon (IEEE Press. Institute of Electrical and Electronics Engineers, 2010)
Comunicació de congrés
Accés obertBiopotential measurements with capacitive electrodes do not need any direct contact between electrode and skin, which saves the time devoted to expose and prepare the contact area when measuring with conductive electrodes. ... -
Multi-signal bathroom scale to assess long-term trends in cardiovascular parameters
Gómez Clapers, Joan; Casanella Alonso, Ramón; Pallàs-Areny, Ramon (IEEE, 2012)
Text en actes de congrés
Accés restringit per política de l'editorialThis paper describes the circuits and signal processing techniques that convert an electronic bathroom scale intended for bioimpedance analysis (BIA) into a compact system to acquire the electrocardiogram (ECG), the ... -
Noise reduction in AC-coupled amplifiers
Serrano Finetti, Roberto Ernesto; Pallàs-Areny, Ramon (2014-07-01)
Article
Accés restringit per política de l'editorialAC-coupled amplifiers are noisier than dc-coupled amplifiers because of the thermal noise of the resistor(s) in the ac-coupling network and the increased contribution of the amplifier input noise current i(n). Both ... -
Noniterative algorithms for electrical resistivity imaging applied to subsurface local anomalies
Gasulla Forner, Manuel; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2005-12)
Article
Accés obertIn this paper, we compare five noniterative (one-step) algorithms for two-dimensional electrical resistivity imaging applied to the location of subsurface local anomalies. Here, we analyze the performance of two backprojection ... -
Novel indices of ventricular repolarization to screen post myocardial infarction patients
Alvarado Serrano, Carlos; Ramos Castro, Juan José; Pallàs-Areny, Ramon (Elsevier, 2006-05)
Article
Accés obertWe propose novel indices of ventricular repolarization intervals, the JTp/JT, Tpe/JTp and Tpe/JT ratios. These indices have been compared with the duration of the ventricular repolarization intervals and other ratios in ... -
Obtención de parámetros cardiovasculares en una báscula electrónica doméstica
Gómez Clapers, Joan; Casanella Alonso, Ramón; Pallàs-Areny, Ramon (2012)
Text en actes de congrés
Accés restringit per política de l'editorialSe presenta un nuevo sistema para obtener parámetros cardiovasculares de forma sencilla y rápida, apto para el uso en entornos extrahospitalarios. Se basa en una báscula electrónica doméstica modificada a la que se ha ... -
Obtención del ECG en una báscula de baño
Díaz Cerecedo, Delia; Casas Piedrafita, Óscar; Pallàs-Areny, Ramon (2012)
Comunicació de congrés
Accés obert -
Obtención robusta de la frecuencia cardiaca en una báscula electrónica domestica
Gilaberte Elvira, Sonia; Casanella Alonso, Ramón; Pallàs-Areny, Ramon (2009-11-18)
Comunicació de congrés
Accés restringit per acord de confidencialitat -
On bio activity related signals from contactless electrode measurements
Pallàs-Areny, Ramon; Casas Piedrafita, Óscar (2016-02-01)
Article
Accés obertIn a recent paper on a displacement current sensor for contactless detection of bio-activity related signals [1], it was stated that “A potential means for human presence detection…is via sensing…human biopotentials” ... -
On bio-activity related signals from contactless electrode measurements
Pallàs-Areny, Ramon; Casas Piedrafita, Óscar (2015)
Article
Accés obert