Ara es mostren els items 10-29 de 127

    • A novel sensor-bridge-to-microcontroller interface 

      Custodio Ruiz, Ángel; Bragós Bardia, Ramon; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2001-05)
      Text en actes de congrés
      Accés obert
      Sensor bridges are usually interfaced to microcontrollers by supplying the bridge with a voltage or current and digitizing the resulting voltage or current after being amplified and low-pass filtered. This paper proposes ...
    • A practical approach to electrode-skin impedance unbalance measurement 

      Spinelli, Enrique M.; Mayosky, Miguel Ángel; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2006-07)
      Article
      Accés obert
      Unbalance between electrode-skin impedances is a major problem in biopotential recordings, leading to increased power-line interference. This paper proposes a simple, direct method to measure that unbalance at power-line ...
    • AC-coupled front-end for biopotential measurements 

      Spinelli, Enrique M.; Mayosky, Miguel Ángel; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2003-03)
      Article
      Accés obert
      AC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of ...
    • An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform 

      Alvarado Serrano, Carlos; Luna Lozano, Pablo Samuel; Pallàs-Areny, Ramon (2016-05-01)
      Article
      Accés obert
      This work describes an algorithm intended to detect the beat-to-beat heart rate from the ballistocardiogram (BCG) obtained from seated subjects. The algorithm is based on the continuous wavelet transform with splines, which ...
    • An improved buffer for bioelectric signals 

      Pallàs-Areny, Ramon; Colominas i Balagué, Josep; Rosell Ferrer, Francisco Javier (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 1989-04-01)
      Article
      Accés obert
      We propose an AC-coupled amplifier that offers a high in-put impedance, thus making it suitable for bioelectric signal amplifi- cation. We also present the necessary formulas for calculating its input impedance and transfer ...
    • Automatic Concealed Heart Rate Detection from the BCG in Seated Position 

      Luna Lozano, P. S.; Pallàs-Areny, Ramon (2015-03-01)
      Article
      Accés obert
      Continuous monitoring of health state is important in elder and chronically ill (but otherwise not critical) patients. Ideally, the patient should not be aware of being continuously monitored. This study describes an ...
    • Automatic detection of ECG ventricular activity waves using continuous spline wavelet transform 

      Alvarado Serrano, Carlos; Arregui, J.; Ramos Castro, Juan José; Pallàs-Areny, Ramon (2005)
      Text en actes de congrés
      Accés obert
      In this study, we present detection algorithms of characteristic points of the QRS and T waves based on the continuous wavelet transform (CWT) with splines. This technique can handle any integer scale and the analysis is ...
    • Basic design of the signal chain in sensor-based measurement systems 

      Pallàs-Areny, Ramon; Casas Piedrafita, Óscar (2022-04-19)
      Report de recerca
      Accés obert
      Sensor signals do not suit direct electronic communication and need further processing before being digitized. Therefore, the requirements of the digitizer add to those needed to fulfill the basic specifications for the ...
    • BiC: Examen 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2014-01-15)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2012-01-24)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2020-01-15)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2013-11-11)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2015-01-09)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2015-01-09)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2013-01-29)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen MQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2019-10-29)
      Examen
      Accés restringit a la comunitat UPC
    • BiC: Examen: Primera part 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2012-11-16)
      Examen
      Accés restringit a la comunitat UPC
    • BiC:Examen FQ 

      Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2014-11-11)
      Examen
      Accés restringit a la comunitat UPC
    • La Bioingeniería en la Escuela 

      Pallàs-Areny, Ramon (Escola Tècnica Superior d'Enginyers de Telecomunicació de Barcelona, 1993)
      Article
      Accés obert
    • Biosensors for m-health 

      Pallàs-Areny, Ramon (2017-06-14)
      Presentació
      Accés obert