Exploració per autor "Pallàs-Areny, Ramon"
Ara es mostren els items 10-29 de 127
-
A novel sensor-bridge-to-microcontroller interface
Custodio Ruiz, Ángel; Bragós Bardia, Ramon; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2001-05)
Text en actes de congrés
Accés obertSensor bridges are usually interfaced to microcontrollers by supplying the bridge with a voltage or current and digitizing the resulting voltage or current after being amplified and low-pass filtered. This paper proposes ... -
A practical approach to electrode-skin impedance unbalance measurement
Spinelli, Enrique M.; Mayosky, Miguel Ángel; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2006-07)
Article
Accés obertUnbalance between electrode-skin impedances is a major problem in biopotential recordings, leading to increased power-line interference. This paper proposes a simple, direct method to measure that unbalance at power-line ... -
AC-coupled front-end for biopotential measurements
Spinelli, Enrique M.; Mayosky, Miguel Ángel; Pallàs-Areny, Ramon (Institute of Electrical and Electronics Engineers, 2003-03)
Article
Accés obertAC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of ... -
An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform
Alvarado Serrano, Carlos; Luna Lozano, Pablo Samuel; Pallàs-Areny, Ramon (2016-05-01)
Article
Accés obertThis work describes an algorithm intended to detect the beat-to-beat heart rate from the ballistocardiogram (BCG) obtained from seated subjects. The algorithm is based on the continuous wavelet transform with splines, which ... -
An improved buffer for bioelectric signals
Pallàs-Areny, Ramon; Colominas i Balagué, Josep; Rosell Ferrer, Francisco Javier (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 1989-04-01)
Article
Accés obertWe propose an AC-coupled amplifier that offers a high in-put impedance, thus making it suitable for bioelectric signal amplifi- cation. We also present the necessary formulas for calculating its input impedance and transfer ... -
Automatic Concealed Heart Rate Detection from the BCG in Seated Position
Luna Lozano, P. S.; Pallàs-Areny, Ramon (2015-03-01)
Article
Accés obertContinuous monitoring of health state is important in elder and chronically ill (but otherwise not critical) patients. Ideally, the patient should not be aware of being continuously monitored. This study describes an ... -
Automatic detection of ECG ventricular activity waves using continuous spline wavelet transform
Alvarado Serrano, Carlos; Arregui, J.; Ramos Castro, Juan José; Pallàs-Areny, Ramon (2005)
Text en actes de congrés
Accés obertIn this study, we present detection algorithms of characteristic points of the QRS and T waves based on the continuous wavelet transform (CWT) with splines. This technique can handle any integer scale and the analysis is ... -
Basic design of the signal chain in sensor-based measurement systems
Pallàs-Areny, Ramon; Casas Piedrafita, Óscar (2022-04-19)
Report de recerca
Accés obertSensor signals do not suit direct electronic communication and need further processing before being digitized. Therefore, the requirements of the digitizer add to those needed to fulfill the basic specifications for the ... -
BiC: Examen
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2014-01-15)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2012-01-24)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2020-01-15)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2013-11-11)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2015-01-09)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2015-01-09)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2013-01-29)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen MQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2019-10-29)
Examen
Accés restringit a la comunitat UPC -
BiC: Examen: Primera part
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2012-11-16)
Examen
Accés restringit a la comunitat UPC -
BiC:Examen FQ
Pallàs-Areny, Ramon (Universitat Politècnica de Catalunya, 2014-11-11)
Examen
Accés restringit a la comunitat UPC -
La Bioingeniería en la Escuela
Pallàs-Areny, Ramon (Escola Tècnica Superior d'Enginyers de Telecomunicació de Barcelona, 1993)
Article
Accés obert -
Biosensors for m-health
Pallàs-Areny, Ramon (2017-06-14)
Presentació
Accés obert