Ara es mostren els items 82-101 de 251

    • Diffusion-reaction model for the internal sulfate attack in concrete 

      Campos, A.; López Garello, Carlos María; Aguado de Cea, Antonio (2016-01)
      Article
      Accés obert
      In the analysis of the behavior of concrete structures affected by expansive problems, it is often necessary to use kinetics models of the reactions involved to assess and predict the magnitude, distribution, and evolution ...
    • Discrete element modelling of the fresh state behavior of pervious concrete 

      Pieralisi, Ricardo; Pialarissi Cavalaro, Sergio Henrique; Aguado de Cea, Antonio (2016-12)
      Article
      Accés obert
      The objective of this paper is to propose a novel numerical approach to evaluate the fresh state behavior of pervious concrete (PC). A new constitutive law applied to Discrete Element Method was developed for the simulation ...
    • Diseño de tanques cilíndricos de ferrocemento para construir en comunidades rurales de países en desarrollo 

      Masó, J; Molins i Borrell, Climent; Aguado de Cea, Antonio (International Centre for Numerical Methods in Engineering (CIMNE), 2005)
      Llibre
      Accés obert
      En este documento se presenta un estudio sobre el diseño y la construcción de depósitos de ferrocemento para países en vías de desarrollo. Se le da un especial énfasis al hecho de que los depósitos que se plantean están ...
    • Diseño óptimo de dovelas de hormigón reforzado con fibras para el revestimiento de túneles 

      Fuente Antequera, Albert de la; Blanco Álvarez, Ana; Pujadas Álvarez, Pablo; Aguado de Cea, Antonio (2015)
      Article
      Accés obert
      El uso del hormigón reforzado con fibras (HRF) para la fabricación de dovelas de túneles es una práctica en aumento. Sin embargo, aún existe cierta inercia al cambio respecto a la solución tradicional de hormigón armado ...
    • Diseño y análisis de secciones de hormigón estructural frente solicitaciones normales 

      Aguado de Cea, Antonio; Fuente Antequera, Albert de la; Arrarte, Diego (Universitat Politècnica de Catalunya. Institut de Ciències de l'Educació, 2010-02-11)
      Comunicació de congrés
      Accés obert
      En esta comunicación se presenta una experiencia piloto en la enseñanza de la materia Hormigón Estructural de la titulación de Ingenieros de Caminos, Canales y Puertos de la UPC, la cual puede ser fácilmente extendida a ...
    • Distribution of fibers in SFRC segments for tunnel linings 

      Carmona, Sergio; Molins i Borrell, Climent; Aguado de Cea, Antonio; Mora, Felipe (2016-01)
      Article
      Accés obert
      This paper presents research results regarding the distribution of steel fibers in concrete used to build precast tunnel segments for Line 9 of the Barcelona Metro. The fiber distribution was studied using the actual fiber ...
    • Dosagem e aplicação de concreto pesado de densidade 4.000 e 4.500 kg/m3 

      Soares Klein, Nayara; Aguado de Cea, Antonio; Pujadas Álvarez, Pablo; Soares, Talita C. (2013)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      Heavyweight concretes are an attractive alternative when heavyweight elements need to fill reduced spaces, because they present high densities and are able to take different forms according to the container where they are ...
    • Double Punch Test to control the energy dissipation in tension of FRC (Barcelona test) 

      Molins i Borrell, Climent; Aguado de Cea, Antonio; Saludes Requena, Sergio (RILEM, 2008)
      Article
      Accés obert
      Current testing methods used to measure tensile properties of Fiber Reinforced Concrete(FRC) are mainly based on bending test of beam specimens. They normally show a considerable scatter that makes difficult the quality ...
    • Double-punch test of fiber-reinforced concrete: effect of specimen origin and size 

      Aire, Carlos; Carmona Malatesta, Sergio; Aguado de Cea, Antonio; Molins i Borrell, Climent (2015-03)
      Article
      Accés restringit per política de l'editorial
      One of the main advantages of the Barcelona test is that the properties of fiber-reinforced concrete (FRC) can be determined by using cylindrical specimens, thereby permitting the use of cores to control the quality of ...
    • Dovelas de hormigón (concreto) reforzado con fibras para el soporte de túneles y pozos verticales 

      Fuente Antequera, Albert de la; Pujadas Álvarez, Pablo; Blanco Álvarez, Ana; Aguado de Cea, Antonio (Asociación Mexicana de Ingeniería de Túneles y Obras Subterráneas (AMITOS), 2018-04)
      Article
      Accés obert
      El empleo del hormigón reforzado con fibras (HRF) para dovelas de anillos de revestimiento de túneles es ya una práctica habitual a nivel nacional e internacional. En este sentido, las ventajas técnicas a las que conduce ...
    • Durability of concrete with electric arc furnace slag aggregate 

      González Ortega, Martha Alejandra; Pialarissi Cavalaro, Sergio Henrique; Rodríguez de Sensale, Gemma; Aguado de Cea, Antonio (Elsevier, 2019-08)
      Article
      Accés obert
      The durability of concrete mixes with EAF slag as aggregate (HS) is studied; mixes with limestone (HC) and barite (HAB) aggregates were used as reference for structural and heavy-weight applications, respectively. Compressive ...
    • Eco-trench: a novel trench solution based on reusing excavated material and a finishing layer of expansive concrete 

      Blanco Álvarez, Ana; Pujadas Álvarez, Pablo; Fernández Rubio, Cristina; Pialarissi Cavalaro, Sergio Henrique; Aguado de Cea, Antonio (Instituto Técnico de la Construcción y del Cemento, 2017-10)
      Article
      Accés obert
      Installing utility pipelines generates a significant amount of trench arisings, which are usually transported to landfills instead of being reused as backfill material. This practice generates CO2 emissions and wastes raw ...
    • Effect of aging on the fracture characteristics and brittleness of a high-strength concrete 

      Gettu, Ravindra; García Álvarez, Víctor Óscar; Aguado de Cea, Antonio (Elsevier, 1998)
      Article
      Accés obert
      Results of notched beam (fracture) tests on a 60 MPa silica fume concrete at the ages of 4, 10, 31 and 232 days are presented. Fracture parameters at the different ages were obtained using the size effect and cohesive ...
    • Effect of gypsum content in sprayed cementitious matrices: early age hydration and mechanical properties 

      Herrera Messen, Carlos; Salvador, Renan Pícolo; Pialarissi Cavalaro, Sergio Henrique; Aguado de Cea, Antonio (2019-01)
      Article
      Accés obert
      Sprayed materials must present short setting times and a fast early strength development for safety and productivity reasons. In order to improve these characteristics, the construction industry has focused on the development ...
    • Effects of an internal sulfate attack and an alkali-aggregate reaction in a concrete dam 

      Campos, A.; López Garello, Carlos María; Blanco Álvarez, Ana; Aguado de Cea, Antonio (2018-03)
      Article
      Accés obert
      The alkali-aggregate reaction and the internal sulfate attack are two chemical reactions that lead to expansions in concrete structures. The former is one of the main causes of expansions in concrete dams and has been ...
    • El paraguas: proyecto de refuerzo, consolidación y ejecución de la obra 

      Fuente Antequera, Albert de la; Aguado de Cea, Antonio (Fundació Privada Institut d'Estudis Estructurals, 2019)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      D. Ildefonso Sánchez del Río diseñó una cubierta de hormigón armado para el mercado de ganado de Pola de Siero (Asturias) que, actualmente, sirve como también como cubierta para la estación de autobuses. Consiste en un ...
    • Electrical impedance as a technique for civil engineer structures surveillance : considerations on the galvanic insulation of samples 

      Torrents Dolz, Josep M.; Juan Garcia, Pablo; Aguado de Cea, Antonio (Institute of Physics, 2007)
      Article
      Accés obert
      Since Electric Impedance Spectroscopy (EIS) has been widely used to determine physical properties of materials, it becomes necessary to evaluate different error contributions. In this work, it is studied the effect of the ...
    • Ensayo de corte tipo Luong para determinar la resistencia a cortante de concreto 

      Aire, Carlos; Molins i Borrell, Climent; Aguado de Cea, Antonio (2013)
      Text en actes de congrés
      Accés restringit per política de l'editorial
    • Ensayo de doble punzonamiento (ensayo Barcelona) para caracterizar el comportamiento del hormigón reforzado con fibra 

      Aire, Carlos; Aguado de Cea, Antonio; Molins i Borrell, Climent (2012)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      Tradicionalmente, para caracterizar el comportamiento del hormigón reforzado con fibra se realizan ensayos de flexotracción en vigas. Sin embargo, existen otros procedimientos que debido a la complejidad y variabilidad de ...
    • Ensayo de doble punzonamiento para concreto reforzado con fibra: efecto del tamaño y origen de la probeta 

      Aire, Carlos; Molins i Borrell, Climent; Aguado de Cea, Antonio (2013)
      Article
      Accés obert
      Traditionally, to characterize the behavior of reinforced concrete with fiber (CRF) flexural tests are performed on beams. However, in accordance with various studies on FRC, it has been seen different variation coefficients ...