Exploració per autor "Gil Mur, Francisco Javier"
Ara es mostren els items 44-63 de 130
-
Effect of blasting treatment and Fn coating on MG63 adhesion and differentiation on titanium: A gene expression study using real-time RT-PCR
Pegueroles Neyra, Marta; Aguirre Cano, Aitor; Engel López, Elisabeth; Pavon-Djavid, Graciela; Gil Mur, Francisco Javier; Planell Estany, Josep Anton; Migonney, Veronique; Aparicio Bádenas, Conrado José (2011-03)
Article
Accés restringit per política de l'editorialBiomaterial surface properties, via alterations in the adsorbed protein layer, and the presence of specific functional groups can influence integrin binding specificity, thereby modulating cell adhesion and differentiation ... -
Effect of blasting treatment and Fn coating on MG63 adhesion and differentiation on titanium: a gene expression study using real-time RT-PCR.
Pegueroles Neyra, Marta; Aguirre Cano, Aitor; Engel López, Elisabeth; Pavon-Djavid, Graciela; Gil Mur, Francisco Javier; Planell Estany, Josep Anton; Migonney, Veronique; Aparicio Bádenas, Conrado José (2011-03-02)
Article
Accés restringit per política de l'editorialBiomaterial surface properties, via alterations in the adsorbed protein layer, and the presence of specific functional groups can influence integrin binding specificity, thereby modulating cell adhesion and differentiation ... -
Effect of microstructure on dry sliding wear behaviour in CuZnAl shape memory alloys
Peña Andrés, Javier; Gil Mur, Francisco Javier; Guilemany, Josep Maria (2002-07)
Article
Accés obertThe main objective of this work has been the characterization of the wear behaviour of the CuZnAl shape memory alloys in their different phases. The weight losses for the different alloys in function of the present phase, ... -
Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs
Espinar, Eduardo; Llamas Carreras, Jose Maria; Barrera Mora, Jose Maria; Ábalos, C.; Gil Mur, Francisco Javier (2013-07-01)
Article
Accés restringit per política de l'editorialNiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic ... -
Enhanced osteoconductivity on electrically charged titanium implants treated by physicochemical surface modifications methods
Fernández Yagüe, Marc-Antoni; Pérez Antoñanzas, Román; Roa Rovira, Joan Josep; Biggs, Manus; Gil Mur, Francisco Javier; Pegueroles Neyra, Marta (2019-06-01)
Article
Accés obertBiomimetic design is a key tenet of orthopedic device technology, and in particular the development of responsive surfaces that promote ion exchange with interfacing tissues, facilitating the ionic events that occur naturally ... -
Estudio del desgaste catastrófico de la circona
Fernández Fairen, Mariano; Gil Mur, Francisco Javier; Martínez, S.; Sala, P.; Delgado, J.A.; Blanco, A. (Sociedad Ibérica de Biomecánica y Biomateriales, 2004-12)
Article
Accés obert -
Estudio histológico e histomorfométrico de la respuesta ósea de implantes dentales en cerdos minipigs
Pegueroles Neyra, Marta; Gil Mur, Francisco Javier (2012-07-15)
Report de recerca
Accés restringit per acord de confidencialitat -
Evaluating mechanical properties and degradation of YTZP dental implants
Sevilla Sánchez, Pablo; Sandino Velazquez, Clara; Arciniegas Angarita, Milena Patricia; Martínez Gomis, Jordi; Peraire, M; Gil Mur, Francisco Javier (2010-01)
Article
Accés restringit per política de l'editorialLately new biomedical grade yttria stabilized zirconia (YTZP) dental implants have appeared in the implantology market. This material has better aesthetical properties than conventional titanium used for implants but long ... -
Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs
Godoy Gallardo, María; Manzanares, Maria Cristina; Sevilla Sánchez, Pablo; Nart, José; Manzanares, Norberto; Manero Planella, José María; Gil Mur, Francisco Javier; Boyd, Steven K.; Rodríguez Rius, Daniel (Elsevier, 2016-07)
Article
Accés obert
Realitzat a/amb: Universitat de Barcelona. Departament de Patologia i Terapèutica Experimental / University of Calgary. McCaig Institute for Bone and Joint HealthThe aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle ... -
Evaluation of titanium dental implants after failure of osseointegration by means of X-ray photoelectron spectroscopy, electron microscopy and histological studies
Lázaro, Pedro; Herrero Climent, Mariano; Gil Mur, Francisco Javier (Springer, 2010)
Article
Accés obertIn this work, we analysed 56 clinically failed and retrieved implants by means of scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and histological studies. The surface contamination was ... -
Fatigue life of bioactive titanium dental implants treated by means of grit-blasting and thermo-chemical treatment
Gil Mur, Francisco Javier; Espinar Escalona, Eduardo; Llamas Carreras, Jose Maria; Sevilla Sánchez, Pablo (2014-04)
Article
Accés restringit per política de l'editorialObjective: This study focuses on the fatigue behavior of titanium dental implants as-received, with a grit-blasted surface and with a new bioactive surface treatment (2Steps). Background: The 2Step process consists of (1) ... -
Fibroblast adhesion and activation onto micro-machined titanium surfaces
Guillem Martí, Jordi; Delgado Garoña, Luis María; Godoy Gallardo, Maria; Pegueroles Neyra, Marta; Herrero, Mariano; Gil Mur, Francisco Javier (2012-03-11)
Article
Accés restringit per política de l'editorialObjectives: Surface modifications performed at the neck of dental implants, in the manner of micro-grooved surfaces, can reduce fibrous tissue encapsulation and prevent bacterial colonization, thereby improving ... -
Fracture and fatigue of titanium narrow dental implants: New trends in order to improve the mechanical response
Velasco Ortega, Eugenio; Flichy Fernández, Antonio; Punset Fuste, Miquel; Jimenez Guerra, Álvaro; Manero Planella, José María; Gil Mur, Francisco Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2019-11-12)
Article
Accés obert
Realitzat a/amb: Universidad de Sevilla / Universitat de València / Universitat Internacional de CatalunyaSixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their ... -
Friction coefficients and wear rates of different orthodontic archwires in artificial saliva
Alfonso, M.V.; Espinar, Eduardo; Llamas, José María; Rupérez de Gracia, Elisa; Manero Planella, José María; Barrera, J.M; Solano, E.; Gil Mur, Francisco Javier (Springer, 2013-05)
Article
Accés restringit per política de l'editorialThe aim of this paper is to analyze the influence of the nature of the orthodontic archwires on the friction coefficient and wear rate against materials used commonly as brackets (Ti–6Al–4V and 316L Stainless Steel). ... -
Functionalization of CoCr surfaces with cell adhesive peptides to promote HUVECs adhesion and proliferation
Castellanos, Maria Isabel; Mas Moruno, Carlos; Grau, Anna; Serra-Picamal, Xavier; Trepat, Xavier; Albericio Palomera, Fernando; Joner, Michael; Gil Mur, Francisco Javier; Ginebra Molins, Maria Pau; Manero Planella, José María; Pegueroles Neyra, Marta (2017-01-30)
Article
Accés obert
Realitzat a/amb: Center for Research in NanoEngineering (CRNE) / Deutsches Herzzentrum München / Institut de Bioenginyeria de CatalunyaBiomimetic surface modification with peptides that have specific cell-binding moieties is a promising approach to improve endothelialization of metal-based stents. In this study, we functionalized CoCr surfaces with RGDS, ... -
I Jornada de R+D+I
Jordana Riba, Francisco de Paula; Serrat Piè, Carles; Gil Mur, Francisco Javier (2010-05-05)
Audiovisual
Accés obert -
Immobilization strategies to functionalize tantalum surfaces with cell-adhesive peptides: physicochemical and biological characterization
Mas Moruno, Carlos; Garrido Dominguez, Beatriz; Rodríguez Rius, Daniel; Rupérez de Gracia, Elisa; Gil Mur, Francisco Javier (Curran, 2014)
Comunicació de congrés
Accés obert -
Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria
Hoyos Nogués, Mireia; Brosel, Sergi; Abramova, Natalia; Muñoz, FJ; Andrey, Bratov; Gil Mur, Francisco Javier; Mas Moruno, Carlos (2016)
Article
Accés obert
Realitzat a/amb: Center for Research in NanoEngineering (CRNE)Peri-implantitis, an inflammation caused by biofilm formation, constitutes a major cause of implant failure in dentistry. Thus, the detection of bacteria at the early steps of biofilm growth represents a powerful strategy ... -
Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
Gil Mur, Francisco Javier; Herrero Climent, Mariano; Lázaro, Pedro; Rios Santos, Jose Vicente (2014-04-10)
Article
Accés restringit per política de l'editorialMicrogap between implant and abutment can produce biological and mechanical problems such as peri-implantitis and/or fatigue failures. The aim of this study was to evaluate microgap size and fatigue ... -
Importance of the roughness and residual stresses of dental implants on fatigue and osseointegration behavior. In vivo study in rabbits
Velasco Ortega, E; Monsalve Guil, L; Jimenez Guerra, A; Ortiz Garcia, Ivan; Moreno Muñoz, Jesus; Nuñez Marquez, Enrique; Pegueroles Neyra, Marta; Pérez Antoñanzas, Román; Gil Mur, Francisco Javier (2016-12-01)
Article
Accés restringit per política de l'editorial
Realitzat a/amb: Universitat Internacional de Catalunya. Facultat d'OdontologiaThis study focuses on the fatigue behavior and bone-implant attachment for the more usual surfaces of the different CP-titanium dental implants. The implants studied were: as-received (CTR), acid etching (AE), spark-anodization ...