Ara es mostren els items 37-56 de 130

    • Dental Implants: Plasma polymerization for antibacterial coatings 

      Buxadera Palomero, Judit; Canal Barnils, Cristina; Gil Mur, Francisco Javier; Rodríguez Rius, Daniel (CRC Press, 2016)
      Capítol de llibre
      Accés restringit per política de l'editorial
      Dental implants are widely used to overcome tooth loss. The material of choice for this application is titanium, due to its excellent mechanical properties, high corrosion resistance, and high biocompatibility. Despite the ...
    • Desenvolupament d’un tractament antiadherent de superfícies de titani per a aplicacions biomèdiques 

      Buxadera Palomero, Judit; Torrent Camarero, Sergi; Gil Mur, Francisco Javier; Rodríguez Rius, Daniel (Servei de Fotocòpies de l'EUETIB, 2013)
      Text en actes de congrés
      Accés obert
      L’ús d’implants de titani per a traumatologia i odontologia és una pràctica molt estesa actualment. El seu èxit, però, es veu afectat pels casos de infeccions que pateixen. En el cas concret dels implants dentals, el 14% ...
    • Desenvolupament d’un tractament antiadherent de superfícies de titani per a aplicacions biomèdiques 

      Buxadera Palomero, Judit; Torrent Camarero, Sergi; Gil Mur, Francisco Javier; Rodríguez Rius, Daniel (EUETIB, 2013-12)
      Text en actes de congrés
      Accés obert
      L’ús d’implants de titani per a traumatologia i odontologia és una pràctica molt estesa actualment. El seu èxit, però, es veu afectat pels casos de infeccions que pateixen. En el cas concret dels implants dentals, el 14% ...
    • Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth 

      Martin Gili, D.; Molmeneu Trias, Meritxell; Fernández Yagüe, Marc-Antoni; Punset Fuste, Miquel; Giner, Li; Armengou, Jaume; Gil Mur, Francisco Javier (2015-07-01)
      Article
      Accés obert
      This study shows the potential risk of microfiltration between two different types of implant-abutment connections screwed at 45 Ncm: external and internal. For the first time the use of a mechanical artificial mouth is ...
    • Development of biomimetic NiTi alloy: influence of thermo-chemical treatment on the physical, mechanical and biological behavior 

      Rupérez de Gracia, Elisa; Manero Planella, José María; Bravo González, Luis-Alberto; Espinar, Eduardo; Gil Mur, Francisco Javier (2016-06)
      Article
      Accés obert
      A bioactive layer, free of nickel, has been performed for its greater acceptability and reliability in clinical applications for NiTi shape memory alloys. In the first step, a safe barrier against Ni release has been ...
    • Development of tantalum scaffold for orthopaedic applications produced by space-holder method 

      Rupérez de Gracia, Elisa; Manero Planella, José María; Riccardi Hernandez, Kiara; Li, Yuping; Aparicio Bádenas, Conrado José; Gil Mur, Francisco Javier (2015-10-15)
      Article
      Accés obert
      Realitzat a/amb:   University of Minnesota School of Dentistry
      In the present study, production of tantalum porous scaffolds using the space holder technique was performed. The effect of size and content of sodium chloride particles, used as space holder, as well as compacting pressure ...
    • Double acid etching treatment of dental implants for enhanced biological properties 

      Giner Tarrida, Lluís; Mercade, Montse; Torrent Camarero, Sergi; Punset Fuste, Miquel; Pérez Antoñanzas, Román; Delgado, Luis M.; Gil Mur, Francisco Javier (2018-04)
      Article
      Accés obert
      Background: The topographical features on the surface of dental implants have been considered as a critical parameter for enhancing the osseointegration of implants. In this work, we proposed a surface obtained by ...
    • Effect of blasting treatment and Fn coating on MG63 adhesion and differentiation on titanium: A gene expression study using real-time RT-PCR 

      Pegueroles Neyra, Marta; Aguirre Cano, Aitor; Engel López, Elisabeth; Pavon-Djavid, Graciela; Gil Mur, Francisco Javier; Planell Estany, Josep Anton; Migonney, Veronique; Aparicio Bádenas, Conrado José (2011-03)
      Article
      Accés restringit per política de l'editorial
      Biomaterial surface properties, via alterations in the adsorbed protein layer, and the presence of specific functional groups can influence integrin binding specificity, thereby modulating cell adhesion and differentiation ...
    • Effect of blasting treatment and Fn coating on MG63 adhesion and differentiation on titanium: a gene expression study using real-time RT-PCR. 

      Pegueroles Neyra, Marta; Aguirre Cano, Aitor; Engel López, Elisabeth; Pavon-Djavid, Graciela; Gil Mur, Francisco Javier; Planell Estany, Josep Anton; Migonney, Veronique; Aparicio Bádenas, Conrado José (2011-03-02)
      Article
      Accés restringit per política de l'editorial
      Biomaterial surface properties, via alterations in the adsorbed protein layer, and the presence of specific functional groups can influence integrin binding specificity, thereby modulating cell adhesion and differentiation ...
    • Effect of microstructure on dry sliding wear behaviour in CuZnAl shape memory alloys 

      Peña Andrés, Javier; Gil Mur, Francisco Javier; Guilemany, Josep Maria (2002-07)
      Article
      Accés obert
      The main objective of this work has been the characterization of the wear behaviour of the CuZnAl shape memory alloys in their different phases. The weight losses for the different alloys in function of the present phase, ...
    • Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs 

      Espinar, Eduardo; Llamas Carreras, Jose Maria; Barrera Mora, Jose Maria; Ábalos, C.; Gil Mur, Francisco Javier (2013-07-01)
      Article
      Accés restringit per política de l'editorial
      NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic ...
    • Enhanced osteoconductivity on electrically charged titanium implants treated by physicochemical surface modifications methods 

      Fernández Yagüe, Marc-Antoni; Pérez Antoñanzas, Román; Roa Rovira, Joan Josep; Biggs, Manus; Gil Mur, Francisco Javier; Pegueroles Neyra, Marta (2019-06-01)
      Article
      Accés obert
      Biomimetic design is a key tenet of orthopedic device technology, and in particular the development of responsive surfaces that promote ion exchange with interfacing tissues, facilitating the ionic events that occur naturally ...
    • Estudio del desgaste catastrófico de la circona 

      Fernández Fairen, Mariano; Gil Mur, Francisco Javier; Martínez, S.; Sala, P.; Delgado, J.A.; Blanco, A. (Sociedad Ibérica de Biomecánica y Biomateriales, 2004-12)
      Article
      Accés obert
    • Estudio histológico e histomorfométrico de la respuesta ósea de implantes dentales en cerdos minipigs 

      Pegueroles Neyra, Marta; Gil Mur, Francisco Javier (2012-07-15)
      Report de recerca
      Accés restringit per acord de confidencialitat
    • Evaluating mechanical properties and degradation of YTZP dental implants 

      Sevilla Sánchez, Pablo; Sandino Velazquez, Clara; Arciniegas Angarita, Milena Patricia; Martínez Gomis, Jordi; Peraire, M; Gil Mur, Francisco Javier (2010-01)
      Article
      Accés restringit per política de l'editorial
      Lately new biomedical grade yttria stabilized zirconia (YTZP) dental implants have appeared in the implantology market. This material has better aesthetical properties than conventional titanium used for implants but long ...
    • Evaluation of bone loss in antibacterial coated dental implants: an experimental study in dogs 

      Godoy Gallardo, María; Manzanares, Maria Cristina; Sevilla Sánchez, Pablo; Nart, José; Manzanares, Norberto; Manero Planella, José María; Gil Mur, Francisco Javier; Boyd, Steven K.; Rodríguez Rius, Daniel (Elsevier, 2016-07)
      Article
      Accés obert
      Realitzat a/amb:   Universitat de Barcelona. Departament de Patologia i Terapèutica Experimental / University of Calgary. McCaig Institute for Bone and Joint Health
      The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle ...
    • Evaluation of titanium dental implants after failure of osseointegration by means of X-ray photoelectron spectroscopy, electron microscopy and histological studies 

      Lázaro, Pedro; Herrero Climent, Mariano; Gil Mur, Francisco Javier (Springer, 2010)
      Article
      Accés obert
      In this work, we analysed 56 clinically failed and retrieved implants by means of scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and histological studies. The surface contamination was ...
    • Fatigue life of bioactive titanium dental implants treated by means of grit-blasting and thermo-chemical treatment 

      Gil Mur, Francisco Javier; Espinar Escalona, Eduardo; Llamas Carreras, Jose Maria; Sevilla Sánchez, Pablo (2014-04)
      Article
      Accés restringit per política de l'editorial
      Objective: This study focuses on the fatigue behavior of titanium dental implants as-received, with a grit-blasted surface and with a new bioactive surface treatment (2Steps). Background: The 2Step process consists of (1) ...
    • Fibroblast adhesion and activation onto micro-machined titanium surfaces 

      Guillem Martí, Jordi; Delgado Garoña, Luis María; Godoy Gallardo, Maria; Pegueroles Neyra, Marta; Herrero, Mariano; Gil Mur, Francisco Javier (2012-03-11)
      Article
      Accés restringit per política de l'editorial
      Objectives: Surface modifications performed at the neck of dental implants, in the manner of micro-grooved surfaces, can reduce fibrous tissue encapsulation and prevent bacterial colonization, thereby improving ...
    • Fracture and fatigue of titanium narrow dental implants: New trends in order to improve the mechanical response 

      Velasco Ortega, Eugenio; Flichy Fernández, Antonio; Punset Fuste, Miquel; Jimenez Guerra, Álvaro; Manero Planella, José María; Gil Mur, Francisco Javier (Multidisciplinary Digital Publishing Institute (MDPI), 2019-11-12)
      Article
      Accés obert
      Realitzat a/amb:   Universidad de Sevilla / Universitat de València / Universitat Internacional de Catalunya
      Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their ...