Ara es mostren els items 33-52 de 64

    • Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch. 

      Bogónez Franco, Francisco; Nescolarde Selva, Lexa Digna; Bragós Bardia, Ramon; Rosell Ferrer, Francisco Javier; Yandiola, Iñigo (2009-06-03)
      Article
      Accés restringit per decisió de l'autor
      The purpose of this study is to compare measurement errors in two commercially available multi-frequency bioimpedance analyzers, a Xitron 4000B and an ImpediMed SFB7, including electrode impedance mismatch. The comparison ...
    • Minimally invasive lung tissue differentiation using electrical impedance spectroscopy: a comparison of the 3- and 4-electrode methods 

      Company Se, Georgina; Nescolarde Selva, Lexa Digna; Pajares Ruiz, Virginia; Torrego Fernández, Alfons; Riu Costa, Pere Joan; Rosell Ferrer, Francisco Javier; Bragós Bardia, Ramon (Institute of Electrical and Electronics Engineers (IEEE), 2021-12-28)
      Article
      Accés obert
      Multiple imaging techniques are used for the diagnosis of lung diseases. The choice of a technique depends on the suspected diagnosis. Computed tomography (CT) of the thorax and positron emission tomography (PET) are imaging ...
    • Monitoring cell monolayers during electroporation: Electrical impedance spectroscopy measurements 

      García Sánchez, Tomás; Guitart, Maria; Sánchez Terrones, Benjamín; Rosell Ferrer, Francisco Javier; Gomez Foix, Anna Maria; Bragós Bardia, Ramon (2013)
      Text en actes de congrés
      Accés obert
      Electroporation or electropermeabilization is a phenomenon observed when lipid bilayers, generally cell membranes, are exposed to high electric field pulses becoming transiently permeable to molecules that under regular ...
    • Multifrequency right-side, localized and segmental BIA obtained with different bioimpedance analyzers 

      Bogónez-Franco, Paco; Nescolarde Selva, Lexa Digna; McAdams, Eric; Rosell Ferrer, Francisco Javier (Institute of Physics (IOP), 2014-12-12)
      Article
      Accés restringit per política de l'editorial
      The aim of this study is to compare two commercial bioimpedance analysers, BioparHom Z-Métrix and Impedimed SFB7, measuring the impedance of three different body segments. The segments measured were 'right-side' (or ...
    • Multisite recording of extracellular potentials produced by microchannel-confined neurons in-vitro 

      Claverol Tinturé, Enrique; Cabestany Moncusí, Joan; Rosell Ferrer, Francisco Javier (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2007-02-28)
      Article
      Accés obert
      Towards establishing electrical interfaces with patterned in vitro neurons, we have previously described the fabrication of hybrid elastomer-glass devices polymer-on-multielectrode array technology and obtained single-electrode ...
    • Muscle fatigue monitoring using a multifrequency bioimpedance technique 

      Vescio, Giovanni; Rosell Ferrer, Francisco Javier; Nescolarde Selva, Lexa Digna; Giovinazzo, Giuseppe (Springer, 2011)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      The objective of this work is to measure the changes of electrical bioimpedance module and phase related to muscular fatigue. The results could also be interesting for medical diagnosis of leg oedema, related to heart ...
    • Myocardial contractility assessed by dynamic electrical impedance measurements during dobutamine stress 

      García Sánchez, Tomás; Jorge, Esther; Amoros Figueras, Gerard; Bragós Bardia, Ramon; Cinca Cuscullola, Joan; Rosell Ferrer, Francisco Javier (Institute of Electrical and Electronics Engineers (IEEE), 2015)
      Comunicació de congrés
      Accés restringit per política de l'editorial
      In this study, the electrical impedance of myocardial tissue is measured dynamically during the cardial cycle. The multisine-based approach used to perform electrical impedance spectroscopy (EIS) measurements allows ...
    • On the zero- and first-order interpolation in synthesized wave for testing purposes 

      Lozano Nieto, Alberto; Rosell Ferrer, Francisco Javier; Pallàs-Areny, Ramon (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 1992-12-02)
      Article
      Accés obert
      This paper deals with the quality requirements of synthesized sine waves reconstructed through a zero- or first- order hold for testing purposes, in particular when a switching demodulator is used. In this case, the ...
    • Performance of an implantable impedance spectroscopy monitor using ZigBee 

      Bogónez Franco, Francisco; Bayés-Genís, Antoni; Rosell Ferrer, Francisco Javier; Bragós Bardia, Ramon (2010-04-04)
      Comunicació de congrés
      Accés restringit per política de l'editorial
      This paper presents the characterization measurements of an implantable bioimpedance monitor with ZigBee. Such measurements are done over RC networks,performing short and long-term measurements, with and without mismatch ...
    • Phase angle by electrical bioimpedance is a predictive factor of hospitalisation, falls and mortality in patients with cirrhosis 

      Román Abal, Eva; Poca, Maria; Amorós Figueras, Gerard; Rosell Ferrer, Francisco Javier; Gely-Nargeot, Marie-Cristine; Nieto, Juan C.; Vidal Alcorisa, Silvia; Urgell Rull, Eulàlia; Ferrero Gregori, Andreu; Alvarado Tapias, Edilmar; Cuyàs Espí, Berta; Hernández Martínez, Elvira; Santesmases, Rosalia; Guarner, Carlos; Escorsell, Àngels; Soriano, German (Nature, 2021-10-14)
      Article
      Accés obert
      The phase angle is a versatile measurement to assess body composition, frailty and prognosis in patients with chronic diseases. In cirrhosis, patients often present alterations in body composition that are related to adverse ...
    • Physiological conditioning by electric field stimulation promotes cardiomyogenic gene expression in human cardiomyocyte progenitor cells 

      Llucía Valldeperas, Aida; Sánchez Terrones, Benjamin; Soler Botija, Carolina; Gálvez Montón, Carolina; Roura, Santiago; Prat Vidal, Cristina; Perea Gil, Isaac; Rosell Ferrer, Francisco Javier; Bragós Bardia, Ramon; Bayés-Genís, Antoni (2014-08-04)
      Article
      Accés obert
      The optimal cell lineage for cardiac-regeneration approaches remains mysterious. Additionally, electrical stimulation promotes cardiomyogenic differentiation of stimulated cells. Therefore, we hypothesized that electrical ...
    • Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography 

      Frangi Caregnato, Alejandro; Riu Costa, Pere Joan; Rosell Ferrer, Francisco Javier; Viergever, Max A. (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2002-06-30)
      Article
      Accés obert
      A framework to analyze the propagation of measurement noise through backprojection reconstruction algorithms in electrical impedance tomography (EIT) is presented. Two measurement noise sources were considered: noise in ...
    • Recognition of fibrotic infarct density by the pattern of local systolic-diastolic myocardial electrical impedance 

      Amoros Figueras, Gerard; Jorge, Esther; García Sánchez, Tomás; Bragós Bardia, Ramon; Rosell Ferrer, Francisco Javier; Cinca Cuscullola, Juan Maria (2016-08-31)
      Article
      Accés obert
      Myocardial electrical impedance is a biophysical property of the heart that is influenced by the intrinsic structural characteristics of the tissue. Therefore, the structural derangements elicited in a chronic myocardial ...
    • Reduction of motion artifacts using a two-frequency impedance plethysmograph and adaptative filtering 

      Rosell Ferrer, Francisco Javier; Cohen, Kevin P.; Webster, John G. (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 1995-10-01)
      Article
      Accés obert
      We measured transthoracic impedance in nine presumed healthy adult subjects with a two-frequency plethysmograph at 57 kHz and 185 kHz. The measurement protocol included periods of normal breathing without motion and periods ...
    • Reference values of the bioimpedance vector components in a Caribbean population 

      Nescolarde Selva, Lexa Digna; Núñez, Ana; Bogónez Franco, Francisco; Lara, Alcibiades; Vaillant, Guillermo; Morales, Ricardo; Rosell Ferrer, Francisco Javier (Elsevier, 2013-06-06)
      Article
      Accés obert
      Background & aims Application of bioelectrical impedance vector analysis (BIVA) requires comparison of an impedance vector to reference intervals derived from healthy subjects. The aim of this work is to obtain reference ...
    • Return-to-play according to GAP in muscle injuries by L-BIA measurements: clinical prognosis. 

      Nescolarde Selva, Lexa Digna; Yanguas Leyes, Javier; Terricabras, Joaquim; Lukaski, Henry; Alomar, Xavier; Rosell Ferrer, Francisco Javier; Rodas Font, Gil (2017)
      Comunicació de congrés
      Accés obert
    • Signal-to-motion artifact ratio versus frequency for impedance pneumography 

      Rosell Ferrer, Francisco Javier; Webster, John G. (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 1995-03-01)
      Article
      Accés obert
      We measured transthoracic impedance between 12.5 and 185 kHz in nine adults. We used a system with two impedance channels, both simultaneously detecting the real part of impedance at two different frequencies. We used only ...
    • Simulation of a magnetic induction method for determining passive electrical property changes of human trunk due to vital activities 

      Mahdavi, Hadiseh; Rosell Ferrer, Francisco Javier (2012)
      Text en actes de congrés
      Accés obert
      Determining the changes in passive electrical properties of human tissues and the geometry changes of the body parts due to breathing and cardiac activity could be a method for monitoring these vital signs. We have designed ...
    • Simulation of a magnetic induction method for determining passive electrical property changes of human trunk due to vital activities 

      Mahdavi, Hadiseh; Rosell Ferrer, Francisco Javier (2012)
      Comunicació de congrés
      Accés obert
    • Sistemas de instrumentación 

      Riu Costa, Pere Joan; Rosell Ferrer, Francisco Javier; Ramos Castro, Juan José (Edicions UPC, 1995)
      Llibre
      Accés restringit a la comunitat UPC
      El núcleo de la obra contiene la descripción de los protocolos físicos y lógicos necesarios para construir un sistema de instrumentación a base de dispositivos comerciales, conectados con un bus IEEE-488 o VXI. Se describen ...