Ara es mostren els items 1-10 de 10

    • Fixed frequency sliding mode-based robust inversion with a full-bridge current DC-link buck-boost 

      Olm Miras, Josep Maria; Biel Solé, Domingo; Fossas Colet, Enric; Cardoner Parpal, Rafel (2014-01)
      Article
      Accés restringit per política de l'editorial
      The substitution of the original switches by a full bridge in a Non-Inverting Buck-Boost converter results in an inverter capable of carrying out step-down and step-up tasks as well under sliding mode control. The control ...
    • G2V and V2G operation 20 kW battery charger 

      Escoda, Jordi; Fontanilles, Joan; Biel Solé, Domingo; Repecho del Corral, Víctor; Cardoner Parpal, Rafel; Griñó Cubero, Robert (2013)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      This paper presents a bidirectional on-board battery charger for Electric Vehicles designed to perform both Grid to Vehicle (G2V) and Vehicle to Grid (V2G) operation. The charger can also operate with single or three-phase ...
    • Sliding mode control of a stand-alone wound rotor synchronous generator 

      Muñoz Aguilar, Raúl Santiago; Dòria Cerezo, Arnau; Fossas Colet, Enric; Cardoner Parpal, Rafel (IEEE Press. Institute of Electrical and Electronics Engineers, 2011-10)
      Article
      Accés restringit per política de l'editorial
      This paper presents a sliding mode control for a wound rotor synchronous machine acting as an isolated generator. The standard dq model of the machine is connected to a resistive load. A switching function is defined ...
    • Odd-harmonic repetitive control of an active filter under varying network frequency: a small-gain theorem-based stability analysis 

      Olm Miras, Josep Maria; Ramos Fuentes, Germán Andrés; Costa Castelló, Ramon; Cardoner Parpal, Rafel (2010)
      Text en actes de congrés
      Accés restringit per decisió de l'autor
      This work deals with the design and analysis of a controller for a shunt active power filter. The design is based on combined feedforward and feedback actions, the last using repetitive control, and aims at the obtention ...
    • Odd-harmonic repetitive control of an active filter under varying network frequency: control design and stability analysis 

      Olm Miras, Josep Maria; Ramos Fuentes, Germán Andrés; Costa Castelló, Ramon; Cardoner Parpal, Rafel (IEEE Press. Institute of Electrical and Electronics Engineers, 2010)
      Text en actes de congrés
      Accés obert
      This work deals with the design and analysis of a controller for a shunt active power filter. The design is based on combined feedforward and feedback actions, the last using repetitive control, and aims at the obtention ...
    • Robust high-order repetitive control of an active filter using an odd-harmonic internal model 

      Ramos Fuentes, Germán Andrés; Costa Castelló, Ramon; Olm Miras, Josep Maria; Cardoner Parpal, Rafel (2010)
      Text en actes de congrés
      Accés obert
      Shunt active power filters have proven to be an efficient means to compensate for the negative effects of nonlinear and reactive loads on the power quality of the electrical distribution network. In this context, the ...
    • Odd-harmonic Repetitive Control of an Active Filter under Varying Network Frequency: Practical Considerations 

      Costa Castelló, Ramon; Olm Miras, Josep Maria; Ramos Fuentes, Germán Andrés; Cardoner Parpal, Rafel (2010)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      This work deals with the design and analysis of a controller for a shunt active power filter. The design is based on combined feedforward and feedback actions, the last using oddharmonic repetitive control, and aims at ...
    • High-Performance Control of a Single-Phase Shunt Active Filter 

      Costa Castelló, Ramon; Griñó Cubero, Robert; Cardoner Parpal, Rafel; Fossas Colet, Enric (2009-11)
      Article
      Accés obert
      Shunt active power filters are devices, connected in parallel with nonlinear and reactive loads, which are in charge of compensating these characteristics in order to assure the quality of the distribution network. This ...
    • Digital Repetitive Control of a Three-Phase Four-Wire Shunt Active Filter 

      Griñó Cubero, Robert; Cardoner Parpal, Rafel; Costa Castelló, Ramon; Fossas Colet, Enric (IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2007-06-30)
      Article
      Accés obert
      Shunt active power filters have been proved as useful elements to correct distorted currents caused by nonlinear loads in power distribution systems. This paper presents an all-digital approach based on a particular ...
    • High performance control of a single-phase shunt active filter 

      Costa Castelló, Ramon; Griñó Cubero, Robert; Cardoner Parpal, Rafel; Fossas Colet, Enric (Institute of Electrical and Electronics Engineers, 2007)
      Text en actes de congrés
      Accés obert
      Shunt active power filters are devices connected in parallel with nonlinear and reactive loads which are in charge of compensating these characteristics in order to assure the quality of the distribution network. This ...