• Calibration process for CTD (Conductivity, Temperature and Depth) 

      Garcia Benadí, Albert; Molino Minero, Erik; Manuel Lázaro, Antonio; Río Fernandez, Joaquín del (2011)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      Detailed herein is the procedure to perform the calibration of a marine observation instrument, in this case a CTD, within the parameters of temperature, pressure and conductivity. It includes a calibration demonstration ...
    • Calibration process of geophones 

      Roset Juan, Francesc Xavier; Garcia Benadí, Albert; Manuel Lázaro, Antonio; González Agudelo, Julián (Institute of Electrical and Electronics Engineers, 2011)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      The purpose of this article is to detail the process of characterization of an geophone in order to obtain the associated uncertainty and its sensitivity.
    • Cone penetration tests in a virtual calibration chamber 

      Arroyo Alvarez de Toledo, Marcos; Butlanska, Joanna; Gens Solé, Antonio; Calvetti, Francesco; Jamiolkowski, Michael (2011)
      Article
      Accés restringit per política de l'editorial
      A virtual calibration chamber was built using a threedimensional model based on the discrete-element method. The chamber was then filled with a scaled granular equivalent of Ticino sand, the material properties of which ...
    • Geophone calibration procedure for ocean bottom seismometers (OBS) 

      Roset Juan, Francesc Xavier; Garcia Benadí, Albert; Manuel Lázaro, Antonio (2010-12-01)
      Article
      Accés obert
      This is a new calibration procedure for geophones using the expanded uncertainly [1] [2] of null-correction created in our laboratories.
    • pH sensor calibration procedure 

      Artero Delgado, Carola; Nogueras Cervera, Marc; Manuel Lázaro, Antonio; Prat Tasias, Jordi; Prat Farran, Joana d'Arc (2013)
      Comunicació de congrés
      Accés obert
      This paper describes the calibration of pH sensor located at the OBSEA marine Observatory. This instrument is based on an industrial pH electrode that is connected to a CTD instrument (Conductivity, Temperature, and ...
    • Proceso de calibración de un equipo submarino de detección sísmica 

      Garcia Benadí, Albert; Roset Juan, Francesc Xavier; Manuel Lázaro, Antonio; Río Fernandez, Joaquín del (2009)
      Text en actes de congrés
      Accés obert
      Se presenta el proceso de calibración diseñado para el geófono, las contribuciones al estudio del cálculo de incertidumbres así como los resultados allados en el mismo proceso de calibración.