Ara es mostren els items 1-20 de 30

    • Artificial intelligence-based protection for smart grids 

      Bakkar, Mostafa; Bogarra Rodríguez, Santiago; Córcoles López, Felipe; Aboelhassan, Ahmed; Wang, Shuo; Iglesias, Javier (2022-07-05)
      Article
      Accés obert
      Lately, adequate protection strategies need to be developed when Microgrids (MGs) are connected to smart grids to prevent undesirable tripping. Conventional relay settings need to be adapted to changes in Distributed ...
    • Behaviour of the doubly fed induction generator exposed to unsymmetrical voltage sags 

      Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim (2012-09)
      Article
      Accés restringit per política de l'editorial
      This study analyses the dynamic behaviour of the doubly fed induction generator exposed to unsymmetrical voltage sags, providing insights into wind turbine fault ride-through capability. The sags are assumed to be caused ...
    • Comparison of simplified models for voltage-source-inverter-fed adjustable-speed drive during voltage sags when the during-event continue mode of operation is active 

      Bogarra Rodríguez, Santiago; Monjo Mur, Lluís; Saura Perisé, Jaime; Córcoles López, Felipe; Pedra Durán, Joaquim (2014-11-13)
      Article
      Accés restringit per política de l'editorial
      Three simplified models for adjustable-speed drives are compared with measurements on an actual drive where the inverter control strategy remains unaltered during the event (also known as continue mode of operation) to ...
    • Control of DFIG-WT under unbalanced grid voltage conditions 

      Luna Alloza, Álvaro; Rodríguez Cortés, Pedro; Lima, Kleber; Córcoles López, Felipe; Watanabe, Edson H.; Teodorescu, R. (2009)
      Comunicació de congrés
      Accés obert
      The voltage oriented control in the synchronous reference frame (VOC-SRF) have been extensively used for controlling wind turbines based on doubly fed induction generators (DFIG-WTs) through the rotor side converter of ...
    • Control of power converters in distributed generation applications under grid fault conditions 

      Rodríguez Cortés, Pedro; Luna Alloza, Álvaro; Muñoz Aguilar, Raúl Santiago; Córcoles López, Felipe; Teodorescu, Remus; Blaabjerg, Frede (IEEE, 2011)
      Text en actes de congrés
      Accés restringit per política de l'editorial
      The operation of distributed power generation systems under grid fault conditions is a key issue for the massive integration of renewable energy systems. Several studies have been conducted to improve the response of ...
    • Control proposals for the operation of power converters in wind power systems 

      Luna Alloza, Álvaro; Aguilar, Daniel; Muñoz Aguilar, Raúl Santiago; Córcoles López, Felipe; Rodríguez Cortés, Pedro (IEEE, 2011)
      Text en actes de congrés
      Accés obert
      The wind turbines based on Doubly Fed Induction Generators (DFIG) represent almost the 60% of the installed windpower worldwide. Nowadays most of the existing algorithms, used for regulating the production of active and ...
    • Detailed study of DFIG-based wind turbines to overcome the most severe grid faults 

      Rolán Blanco, Alejandro; Pedra Durán, Joaquim; Córcoles López, Felipe (2014-11-01)
      Article
      Accés restringit per política de l'editorial
      This paper studies the effects of voltage sags caused by faults on doubly-fed induction generators to overcome grid faults. A wide range of sag duration and depth values is considered. It is observed that sag duration ...
    • Discrete fault-clearing instant influence on the simulation of voltage-source-inverter-fed adjustable-speed drives subjected to voltage sags 

      Córcoles López, Felipe; Bogarra Rodríguez, Santiago; Pedra Durán, Joaquim; Luna Alloza, Álvaro (2011-05)
      Article
      Accés restringit per política de l'editorial
      This study analyses the influence of modelling sags with discrete fault-clearing instants on the behaviour of adjustablespeed drives (ASDs) subjected to sags caused by faults. The effects are compared with those of sags ...
    • Doubly fed induction generator subject to symmetrical voltage sags 

      Rolán Blanco, Alejandro; Córcoles López, Felipe; Pedra Durán, Joaquim (2011-12)
      Article
      Accés restringit per política de l'editorial
      The aim of this paper is to analyze the dynamic behavior of the doubly fed induction generator (DFIG) subject to symmetrical voltage sags caused by three-phase faults. A simple control algorithm is considered and assumed ...
    • Field programmable gate array-based smart switch to avoid inrush current in PV installations 

      Martínez Figueroa, Gerardo de Jesús; Córcoles López, Felipe; Bogarra Rodríguez, Santiago (Multidisciplinary Digital Publishing Institute (MDPI), 2024-02-01)
      Article
      Accés obert
      This paper introduces an FPGA-based implementation of a smart switch designed to avoid inrush currents occurring during the connection of single-phase transformers utilized in grid-connected photovoltaic (PV) systems. The ...
    • FPGA-based smart sensor to detect current transformer saturation during Inrush current measurement 

      Martínez Figueroa, Gerardo de Jesús; Córcoles López, Felipe; Bogarra Rodríguez, Santiago (Multidisciplinary Digital Publishing Institute (MDPI), 2023-01-01)
      Article
      Accés obert
      Current transformer saturation affects measurement accuracy and, consequently, protection reliability. One important concern in the case of overcurrent protections is the discrimination between faults and inrush current ...
    • Grid synchronization for advanced power processing and FACTS in wind power systems 

      Luna Alloza, Álvaro; Rocabert Delgado, Joan; Vázquez Guzmán, Gerardo; Rodríguez Cortés, Pedro; Teodorescu, Remus; Córcoles López, Felipe (2010)
      Text en actes de congrés
      Accés obert
      The high penetration of wind power systems in the electrical network has introduced new issues in the stability and transient operation of the grid. By means of providing advanced functionalities to the existing power ...
    • Multi-layer smart fault protection for secure smart grids 

      Bakkar, Mostafa; Bogarra Rodríguez, Santiago; Córcoles López, Felipe; Al Hanaineh, Wael Hasan Ahmad (Institute of Electrical and Electronics Engineers (IEEE), 2023-07)
      Article
      Accés obert
      The trend toward Smart grid (SG) is increasing significantly by incorporating Distributed Generators (DGs), which leads to new challenges, especially in protection systems. SGs should strengthen robust environments against ...
    • On fixed-speed WT generator modeling for rotor speed stability studies 

      Pedra Durán, Joaquim; Córcoles López, Felipe; Monjo Mur, Lluís; Bogarra Rodríguez, Santiago; Rolán Blanco, Alejandro (2012-02)
      Article
      Accés restringit per política de l'editorial
      This paper analyzes fixed-speed induction generator modeling oriented to rotor speed stability studies. The single- and double-cage models are compared. The effects of symmetrical voltage sags on generator behavior are ...
    • Overcurrent protection based on ANNs for smart distribution networks with grid-connected VSIs 

      Bakkar, Mostafa; Bogarra Rodríguez, Santiago; Córcoles López, Felipe; Iglesias, Javier (2020-12-16)
      Article
      Accés obert
      Recently, the global concern for protection coordination is growing with the impact of distributed generators connected to medium voltage distribution system. Effective protection strategies need to be developed in order ...
    • Parameter estimation of squirrel-cage motors with parasitic torques in the torque–slip curve 

      Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2015-04-16)
      Article
      Accés obert
      This paper studies parasitic torques in steady-state torque–slip curves of squirrel-cage induction motors. The curves of nine motors (small, medium and large size units), three of which were measured in the range s = 2 ...
    • Parameter estimation of wound-rotor induction motors from transient measurements 

      Kojooyan, Hengameh; Monjo Mur, Lluís; Córcoles López, Felipe; Pedra Durán, Joaquim (2014-06)
      Article
      Accés restringit per política de l'editorial
      A new method for determination of the steady-state equivalent circuit parameters of wound-rotor induction motors using experimental data from starting transient measurements is presented. The algorithm data are the stator ...
    • Power control strategies during voltage sags according to Spanish grid code 

      Bogarra Rodríguez, Santiago; Córcoles López, Felipe; Saura Perisé, Jaime; Moreno Eguilaz, Juan Manuel; Bakkar, Mostafa (2018)
      Text en actes de congrés
      Accés obert
      In order to connect any power converters into the grid there are some grid requirements to insure the safe operation of the grid. So, the control of the converters especially during abnormal ...
    • Power quality aspects of smart grids 

      Bollen, Math H.J.; Zhong, Jin; Zavoda, Francisc; Meyer, Jan; McEachern, Alex; Córcoles López, Felipe (2010)
      Text en actes de congrés
      Accés obert
      This paper gives an overview of the smart grids developments, seen from a power-quality viewpoint; describes the main relations between smart grids and power quality, and goes into some detail for some of the aspects. ...
    • Reduced-order models of squirrel-cage induction generators for fixed-speed wind turbines under unbalanced grid conditions 

      Rolán Blanco, Alejandro; Córcoles López, Felipe; Bogarra Rodríguez, Santiago; Monjo Mur, Lluís; Pedra Durán, Joaquim (2016-06)
      Article
      Accés obert
      This paper develops a study of reduced-order models for squirrel-cage induction generators used in the fixed-speed wind turbines. The squirrel-cage of these generators must be modeled with a double-cage for accuracy purposes. ...