Ara es mostren els items 4-12 de 12

  • Fault tolerant control for a second order LPV system using adaptive control methods 

    Vargas Martinez, Adriana; Garza Castañón, Luís Eduardo; Puig Cayuela, Vicenç; Morales Menendez, Ruben (2013)
    Text en actes de congrés
    Accés restringit per política de l'editorial
    A Fault Tolerant Control (FTC) reconfigurable structure for a second order nonlinear process is developed. This structure is based on a Model Reference Adaptive Control (MRAC) with a H1 Gain Scheduling controller designed ...
  • Leak signature space: an original representation for robust leak location in water distribution networks 

    Casillas, Myrna V.; Garza Castañón, Luís Eduardo; Puig Cayuela, Vicenç; Vargas Martinez, Adriana (2015-03-01)
    Article
    Accés obert
    In this paper, an original model-based scheme for leak location using pressure sensors in water distribution networks is introduced. The proposed approach is based on a new representation called the Leak Signature Space ...
  • Methodology for actuator fault tolerance evaluation of linear constrained MPC: application to the Barcelona water network 

    Robles, Deneb; Puig Cayuela, Vicenç; Ocampo-Martínez, Carlos; Garza Castañón, Luís Eduardo (2012)
    Text en actes de congrés
    Accés restringit per política de l'editorial
    This paper presents a methodology to evaluate the admissibility of actuator fault configurations (AFC) when Linear Constrained Model Predictive Control (LCMPC) is used. The methodology combines the use of structural ...
  • MRAC + H8 fault tolerant control for linear parameter varying systems 

    Vargas Martinez, Adriana; Puig Cayuela, Vicenç; Garza Castañón, Luís Eduardo; Morales Menendez, Ruben (2010)
    Text en actes de congrés
    Accés restringit per política de l'editorial
    Two different schemes for Fault Tolerant Control (FTC) based on Adaptive Control, Robust Control and Linear Parameter Varying (LPV) systems are proposed. These schemes include a Model Reference Adaptive Controller for an ...
  • Optimal sensor placement for leak location in water distribution networks using evolutionary algorithms 

    Casillas, Myrna V.; Garza Castañón, Luís Eduardo; Puig Cayuela, Vicenç (2015-11-01)
    Article
    Accés obert
    In this paper, a sensor placement approach to improve the leak location in water distribution networks is proposed when the leak signature space (LSS) method is used. The sensor placement problem is formulated as an integer ...
  • Optimal sensor placement for leak location in water distribution networks using genetic algorithms 

    Casillas, Myrna V.; Puig Cayuela, Vicenç; Garza Castañón, Luís Eduardo; Rosich, Albert (2013-11-04)
    Article
    Accés obert
    This paper proposes a new sensor placement approach for leak location in water distribution networks (WDNs). The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists ...
  • Optimal sensor placement for leak location in water distribution networks using genetic algorithms 

    Casillas, Myrna V.; Puig Cayuela, Vicenç; Garza Castañón, Luís Eduardo; Rosich, Albert (2013)
    Text en actes de congrés
    Accés restringit per política de l'editorial
    In this paper, a new approach for sensor placement in water distribution networks (WDN) is proposed. The sensor placement problem is formulated as an integer optimization problem. The optimization criterion consists in ...
  • Robust MRAC-based fault tolerant control for additive and multiplicative faults in nonlinear systems 

    Vargas Martínez, Adriana; Garza Castañón, Luís Eduardo; Puig Cayuela, Vicenç; Morales Menéndez, Rubén (IFAC, 2012)
    Text en actes de congrés
    Accés restringit per decisió de l'autor
    In this paper, three different types of faults (abrupt-additive, gradual-additive and multiplicative) are introduced to two new reconfigurable structures for Fault Tolerant Control (FTC) of a Single Input- Single Output ...
  • Sensor placement for leak location in water distribution networks using the leak signature space 

    Casillas Ponce, Myrna Violeta; Garza Castañón, Luís Eduardo; Puig Cayuela, Vicenç (International Federation of Automatic Control (IFAC), 2015)
    Text en actes de congrés
    Accés obert
    In this paper, a sensor placement approach to improve the leak location in water distribution networks is proposed. The sensor placement problem is formulated as an integer optimization problem where the criterion to ...